HP Surestore Disk Array 12h HP SureStore E Disk Array 12H User's and Service M - Page 145
during an Add Physical Drive, enabled. Because Auto
View all HP Surestore Disk Array 12h manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 145 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 48/0x30 Cancel Rebuild N NA With Auto- Rebuild Enabled None An attempt was made to cancel a rebuild operation while Auto-Rebuild was enabled. Because AutoRebuild is enabled, the rebuild would only start up again after the cancel, rendering it ineffective. Therefore the controller always rejects a cancel rebuild command while Auto-Rebuild is enabled. 49/0x31 Disk Drive Stamp Write Failed Y Single Disk Drive In order to make a disk drive a Occurrence See accompanying errors Controller Internal SCSI Bus member of a disk set it must have a stamp written onto it by the controller. This error indicates that the writing or updating of the stamp failed during an Add Physical Drive command, causing the command to fail. This is typically caused by disk drive errors. 145