HP Surestore Disk Array 12h HP SureStore E Disk Array 12H User's and Service M - Page 180
Failed, Entered, Isolation Mode
View all HP Surestore Disk Array 12h manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 180 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 213/0xd5 Secondary Controller Failed, Entered Isolation Mode Y Ignore if Controller corrected by Backplane power cycle A controller was discovered to be bad during power on. Specifically, the secondary controller appears to have failed due to an event which caused isolation mode to be entered. In isolation mode controller X becomes the primary controller and controller Y is offline. This may be recovered by power cycle. 214/0xd6 Secondary Controller Failed, Entered Separation Mode Y Ignore if Controller corrected by Backplane reset or power cycle A controller was discovered to be bad during power on. Specifically, the secondary controller appears to have failed due to an event which caused separation mode to be entered. In separation mode, the NVRAM contents is not mirrored between controllers. This may be recovered by reset or power cycle. 180