HP Surestore Disk Array 12h HP SureStore E Disk Array 12H User's and Service M - Page 151
Aborted By Hot, By Host Abort
![]() |
View all HP Surestore Disk Array 12h manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 151 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 75/0x4b Internal Data Transfer Aborted By Hot Plug N NA None A data transfer with the disk drive failed due to a hot-plug event on the channel. When performing RAID 1 mirrored transfers, a hot plug event may disrupt the transfers on both SCSI channels in use. 76/0x4c Internal SCSI Bus State Error N Single Controller A disk drive responded Occurrence Internal SCSI Bus Disk Drive incorrectly. The result was an internal SCSI bus reset, and a hot-plug recovery sequence to regenerate the bus state. The control panel display may indicate "verifying drives" as a result of the internal bus reset. 77/0x4d Write Sequence N In Cache Broken By Host Abort Ignore None A part of a write cache stream was aborted by the host. The failed write was forced because the operation could not be completed. This is a normal part of an abort operation. The host should retry the operation. 78/0x4e Silent Disk Drive Error Recovery N NA None On a previous attempt(s), the disk drive failed the I/O. The controller retried the I/O and the drive returned good status. 79/0x4f Check Condition From Disk Drive With No Sense Y Single Occurrence Disk Drive The disk drive returned a check condition with no sense data. The controller's retries are exhausted or the I/O is not retryable. 151
![](/manual_guide/products/hewlettpackard-surestore-disk-array-12h-hp-surestore-e-disk-array-12h-users-service-manual-c544590901-1999-9011302/151.png)