HP Surestore Disk Array 12h HP SureStore E Disk Array 12H User's and Service M - Page 162
Added To Disk
View all HP Surestore Disk Array 12h manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 162 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 144/0x90 Disk Drive Installed Y Ignore - Operator Activity None The controller has detected the installation of a new disk drive. This event occurs regardless of the disposition of the drive toward the disk set. The disk drive ID number assigned to the drive installed appears in the component identifier field of this log entry. A disk drive ID number consisting of the controller serial number followed by a 0 indicates that the disk drive ID number has not yet been assigned. 145/0x91 Disk Drive Added To Disk Set Y Ignore - Operator activity None The controller has included a new disk drive in the disk set. This event occurs only when a disk drive that was not previously a member of the disk set becomes a member. It does NOT occur when a down, failed, or missing disk is returned to ready status. The disk drive ID number assigned to the drive added appears in the component identifier field of this log entry. 162