HP Surestore Disk Array 12h HP SureStore E Disk Array 12H User's and Service M - Page 169
No Error On, Operator Error
View all HP Surestore Disk Array 12h manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 169 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 170/0xaa Internal SCSI Reassign Completed Y See disk drive Disk Drive vendor's reassign rate spec. The controller successfully completed a sparing operation. The reported FRU is the slot number. 171/0xab Internal SCSI Y Ignore None Reassign Canceled A sparing operation was canceled, typically due to a hog plug event on the bus. The sparing operation will not be retried until another the bad block is accessed again. The reported FRU is the slot number. 172/0xac No Error On Disk Media After Medium Error Y Ignore unless Disk Drive medium error recurs The controller has determined that media for which a disk drive had reported a MEDIUM ERROR is actually OK. The data stored at the affected block may or may not have been recovered. The reported FRU is the slot number. 173/0xad Incompatible RAM Image Revision Y Ignore - None Operator Error The NVRAM image stored on the disk set when it was shutdown is not compatible with the current version of controller firmware. This is typically caused when upgrading controller firmware. Returning to the previous firmware revision will correct this problem without data loss. 169