HP Surestore Disk Array 12h HP SureStore E Disk Array 12H User's and Service M - Page 45
HP SureStore E Disk Array 12H Controller, System State: Ready
View all HP Surestore Disk Array 12h manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
HP SureStore E Disk Array 12H Controller Firmware Download Procedure 6. Verify updated firmware revisions on both controllers using ARMServer (arraydsp -c ) or front panel. The following table shows the proper front panel commands to verify the firmware on the array: KEY CANCEL CANCEL MENU - ENTER + + + + DISPLAY "Ready" "Language" "View Settings" "System State: Ready" "Primary Cntrl: __" "SCSI ID x:__" "SCSI ID y __ "Firmware: HP__" 7. If ARMServer issues a "switch controller" command, you may have to repeat step 5 (download). NOTE! In some older versions of ARMServer, the download command had a problem recognizing the primary array controller. This happens when the primary array controller SCSI ID is a higher number than the secondary array controller SCSI ID. If this problem occurs, the download command will issue a "switch controller" command and then stop. When this happens, issuing the download command again causes the download to complete properly. 8. The disk array will display the "Ready" state when the download command has completed. Controller 45