Hitachi 7K320 Specifications - Page 103
Initialize Device Parameters 91h
![]() |
UPC - 890552647200
View all Hitachi 7K320 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 103 highlights
7K320 (SATA) OEM Specification 14.12 Initialize Device Parameters (91h) Command Block Output Registers Register 76543210 Data -------- Feature -------- Sector Count VVVVVVVV LBA Low -------- LBA Mid -------- LBA High -------- Device - - - - HHHH Command 10010001 Command Block Input Registers Register 76543210 Data -------- Error ...See Below... Sector Count -------- LBA Low -------- LBA Mid -------- LBA High -------- Device -------- Status ...See Below... Error Register 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AM N 000 0 0V0 0 Table 68 Initialize Device Parameters Command (91h) Status Register 7 6 5 4 3 2 1 0 BSY RDY DF DSC DRQ COR IDX ERR 0 0 0 - - 0 0V The Initialize Device Parameters command enables the host to set the number of sectors per track and the number of heads minus 1, per cylinder. Words 54-58 in Identify Device Information reflects these parameters. The parameters remain in effect until the following events: Another Initialize Device Parameters command is received. The device is powered off. Soft reset occurs and the Set Feature option of CCh is set Output Parameters To The Device Sector Count The number of sectors per track. 0 does not mean there are 256 sectors per track, but there is no sector per track. H The number of heads minus 1 per cylinder. The minimum is 0 and the maximum is 15. Page 103 of 176
![](/manual_guide/products/hitachi-7k320-specifications-e740aea/103.png)