Hitachi 7K320 Specifications - Page 160
Standby Immediate E0h/94h
![]() |
UPC - 890552647200
View all Hitachi 7K320 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 160 highlights
7K320 (SATA) OEM Specification 14.42 Standby Immediate (E0h/94h) Command Block Output Registers Register 76543210 Data -------- Feature -------- Sector Count -------- LBA Low -------- LBA Mid -------- LBA High -------- Device -------- Command 11100000 Command Block Input Registers Register 76543210 Data -------- Error ...See Below... Sector Count -------- LBA Low -------- LBA Mid -------- LBA High -------- Device -------- Status ...See Below... Error Register 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AM N 000 0 0V0 0 Table 127 Standby Immediate Command (E0h/94h) Status Register 7 6 5 4 3 2 1 0 BSY RDY DF DSC DRQ COR IDX ERR 0V0V - 0 0V The Standby Immediate command causes the device to enter Standby mode immediately. When this command is issued, the device confirms the completion of the cached write commands. Then the device is spun down, but the interface remains active. If the device is already spun down, the spin down sequence is not executed. During the Standby mode, the device will respond to commands, but there is a delay while waiting for the spindle to reach operating speed. The Standby Immediate command will not affect the auto power down timeout parameter. Page 160 of 176
![](/manual_guide/products/hitachi-7k320-specifications-e740aea/160.png)