Hitachi 7K320 Specifications - Page 70

Non-Data Commands

Page 70 highlights

7K320 (SATA) OEM Specification  Security Set Password  Security Unlock  Set Max Set Password  Set Max Unlock  S.M.A.R.T Write Log Sector  Write Buffer  Write Log Ext  Write Multiple  Write Multiple Ext  Write Sector(s)  Write Sector(s) Ext Execution includes the transfer of one or more 512 byte (>512 bytes on Write Long) sectors of data from the host to the device. If the device detects an invalid parameter, then it will abort the command by setting BSY=0, ERR=1, ABT=1. If an uncorrectable error occurs, the device will set BSY=0 and ERR=1, store the error status in the Error Register. The registers will contain the location of the sector in error. The errored location will be reported with CHS mode or LBA mode. The mode is decided by mode select bit (bit 6) of Device register on issuing the command. 13.3 Non-Data Commands These commands are:  Check Power Mode  Device Configuration Freeze Lock  Device Configuration Restore  Execute Device Diagnostic  Flush Cache  Flush Cache Ext  Format Unit  Idle  Idle Immediate  Idle Immediate with Unload option  Initialize Device Parameters  Read Native Max Address  Read Native Max Address Ext  Read Verify Sector(s)  Read Verify Sector(s) Ext  Recalibrate  Security Erase Prepare  Security Freeze Lock  Seek  Sense Condition  Set Features  Set Max Address  Set Max Address Ext  Set Max Lock  Set Max Freeze Lock  Set Multiple Mode  Sleep  S.M.A.R.T. Disable Operations  S.M.A.R.T. Enable/Disable Attribute Autosave  S.M.A.R.T. Enable/Disable Automatic Off-line  S.M.A.R.T. Enable Operations  S.M.A.R.T. Execute Off-line Immediate  S.M.A.R.T. Return Status  S.M.A.R.T. Save Attribute Values  Standby  Standby Immediate Page 70 of 176

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176

7K320 (SATA) OEM Specification
Page 70 of 176
Security Set Password
Security Unlock
Set Max Set Password
Set Max Unlock
S.M.A.R.T Write Log Sector
Write Buffer
Write Log Ext
Write Multiple
Write Multiple Ext
Write Sector(s)
Write Sector(s) Ext
Execution includes the transfer of one or more 512 byte (>512 bytes on Write Long) sectors of data
from the host to the device.
If the device detects an invalid parameter, then it will abort the command by setting BSY=0, ERR=1,
ABT=1.
If an uncorrectable error occurs, the device will set BSY=0 and ERR=1, store the error status in the
Error Register. The registers will contain the location of the sector in error. The errored location will
be reported with CHS mode or LBA mode. The mode is decided by mode select bit (bit 6) of Device
register on issuing the command.
13.3
Non-Data Commands
These commands are:
Check Power Mode
Device Configuration Freeze Lock
Device Configuration Restore
Execute Device Diagnostic
Flush Cache
Flush Cache Ext
Format Unit
Idle
Idle Immediate
Idle Immediate with Unload option
Initialize Device Parameters
Read Native Max Address
Read Native Max Address Ext
Read Verify Sector(s)
Read Verify Sector(s) Ext
Recalibrate
Security Erase Prepare
Security Freeze Lock
Seek
Sense Condition
Set Features
Set Max Address
Set Max Address Ext
Set Max Lock
Set Max Freeze Lock
Set Multiple Mode
Sleep
S.M.A.R.T. Disable Operations
S.M.A.R.T. Enable/Disable Attribute Autosave
S.M.A.R.T. Enable/Disable Automatic Off-line
S.M.A.R.T. Enable Operations
S.M.A.R.T. Execute Off-line Immediate
S.M.A.R.T. Return Status
S.M.A.R.T. Save Attribute Values
Standby
Standby Immediate