Configuration Information, The Configuration Information window

Page 57 highlights

Notes 1. Be sure to check the System Management Processor check box in the Netfinity Serial Connection Control window when you create the Serial Connection Control entry. If this check box is not checked, the connection with the remote system management subsystem will fail. A null modem connection does not require that this box be checked. 2. When using Serial Connection Control to configure a Dialout Entry for use by the Advanced System Management service, be sure to enter the Login ID and Password for access to the remote system's system management subsystem, not the User ID and Password for access to Netfinity services on the remote system. 3. When creating a Serial Connection Control entry to establish a null modem connection to a remote system's Advanced System Management Adapter or controller, make sure that the Port Baud Rate value (configured using the Serial Connection Control service) is set to match the Baud Rate value (configured using the Advanced System Management service) of the target system. If the Port Baud Rate and the Baud Rate values do not match, the connection will fail. Configuration Information: The Configuration Information window (shown in Figure 1) contains detailed information about the system management subsystem, including RAM microcode, ROM microcode, and device-driver information. Configuration Information - SP NULL modem Service Processor Vital Product Information ROM Firmware RAM Firmware Revision : 1 Part Number : 76H6130 File Name : $80C5102.BIN Date : 09-09-96 Check Sum : 0 Revision : 10 Part Number : 76H6848 File Name : $80C5102.BIN Date : 08-13-97 Check Sum : 80 Hardware Revision : 244 Device Driver Version : 1.0 OS2 Cancel Help Figure 1. The Configuration Information window Netfinity 7000-M10 - Type 8680 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278

Notes
1.
Be sure to check the
System Management
Processor
check box in the Netfinity Serial
Connection Control window when you create the
Serial Connection Control entry.
If this check box
is not checked, the connection with the remote
system management subsystem will fail.
A null
modem connection does not require that this box
be checked.
2.
When using Serial Connection Control to
configure a Dialout Entry for use by the
Advanced System Management service, be sure
to enter the Login ID and Password for access to
the remote system's system management
subsystem, not the User ID and Password for
access to Netfinity services on the remote
system.
3.
When creating a Serial Connection Control entry
to establish a null modem connection to a remote
system's Advanced System Management Adapter
or controller, make sure that the
Port Baud Rate
value (configured using the Serial Connection
Control service) is set to match the
Baud Rate
value (configured using the Advanced System
Management service) of the target system.
If the
Port Baud Rate
and the
Baud Rate
values do
not match, the connection will fail.
Configuration Information:
The Configuration
Information window (shown in Figure
1) contains detailed
information about the system management subsystem,
including RAM microcode, ROM microcode, and
device-driver information.
Configuration
Information
-
SP NULL modem
Service
Processor
Vital
Product
Information
ROM
Firmware
Hardware
Revision
:
244
Device
Driver
Version
:
1.0
OS2
Revision
:
1
Part
Number
:
76H6130
File
Name
:
$80C5102.BIN
Date
:
09-09-96
Check
Sum
:
0
Revision
:
10
Part
Number
:
76H6848
File
Name
:
$80C5102.BIN
Date
:
08-13-97
Check
Sum
:
80
RAM
Firmware
Cancel
Help
Figure 1. The Configuration Information window