IBM 86807RY Hardware Maintenance Manual - Page 198
PCI Sensor Card, Memory DIMM Verify
UPC - 087944491972
View all IBM 86807RY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 198 highlights
Error Code/Symptom 180-XXX-002 (LED test failed) 180-XXX-003 (LED test failed) 180-XXX-004 (PCI Power/Attention LED tests failed) 180-XXX-005 (Retention bracket failure) 180-XXX-006 (ASPI not loaded) 180-XXX-007 (DASD LED failed, see message for slot) 185-XXX-001 (Intrusion Security test failed) 185-XXX-002 (Intrusion Security test failed) 201-004-CDD (Failed Memory Test) CDD: C = Card number DD = DIMM number (silk screened) 201-204-999 (Failed memory test multiple FRUs) 201-XXX-001 (Failed ECC test) 202-XXX-000 (Failed System Cache test) 206-XXX-XXX (Failed Diskette Drive test) 215-XXX-000 (Failed CD-ROM test) 217-XXX-001 (Failed BIOS Fixed Disk test) FRU/Action 1. Memory Card 1 2. System Management Card 1. Memory Card 2 2. System Management Card 1. I/O Board 1. PCI Sensor Card 2. I/O Board 1. SCSI Cable 2. SCSI Backplane 3. I/O Function Card 1. Cable 2. DASD backplane 1. Intrusion (C2 Security) Cable 2. Front Panel 3. I/O Function Card 1. Intrusion (C2 Security) Cable 2. Front Panel 3. I/O Function Card 1. Memory DIMM (see message for Card/DIMM) 2. Memory Card 1. Memory DIMM (see message for Card/DIMM) 2. Memory Card (see message for Card/DIMM) 1. Memory DIMM (Verify failing FRU in system error log.) 1. BSP Processor 2. Processor Board 1. Diskette Drive cable 2. Diskette Drive 3. I/O Function Card 1. CD-ROM cable 2. CD-ROM drive 3. I/O Board 1. Fixed Disk 1 190 Netfinity Server HMM