Features and specifications The following table provides a summary of the features and specifications of the BladeCenter unit. Depending on the model, some features might not be available, or some specifications might not apply. Media tray (on front): Upgradeable microcode: Environment: v Optical drive (optional) v Management-module firmware v Air temperature: v Two USB v2.0 ports v Front system LED panel Blade bays (on front): 14 hot-swap blade-server bays Module bays (on front): Four hot-swap power-module bays Module bays (on rear): v Two hot-swap management-module bays v Ten hot-swap I/O-module bays v Two hot-swap blower bays Power modules: v Minimum: Two hot-swap power modules that are configured for redundant operation v Maximum: Four hot-swap power modules that provide redundancy to all BladeCenter components Redundant cooling: Two variable-speed hot-swap blowers Management module: v Minimum: One hot-swap advanced management module. v Maximum: Two hot-swap advanced management modules: one active, one hot stand-by. v I/O-module firmware (not all I/O module types) v Blade-server firmware Security features: v Login password for remote connection v Secure Sockets Layer (SSL) security for remote management access Predictive Failure Analysis (PFA) alerts: v Blowers v Blade-dependent features Size (9 U): v Height: 400.1 mm (15.75 in. or 9 U) v Depth: 711.2 mm (28 in.) v Width: 482.6 mm (19 in.) v Weight: - Full configured weight with blade servers: Approximately 158.8 kg (350 lbs) - Empty chassis without modules or blade servers: Approximately 40.82 kg (90 lbs) - BladeCenter unit on: - Altitude: 0 to 914 m (3000 ft) 10° to 35°C (50° to 95°F) - Altitude: 914 m to 2134 m (3000 ft to 7000 ft) 10° to 32°C (50° to 90°F) - BladeCenter unit off: -40° to 60°C (-40° to 140°F). v Humidity: 8% to 80% v Acoustics: declared sound power level: 7.5 bels1 Electrical input: v Sine-wave input (50-60 Hz single-phase) required v Input voltage: - Minimum: 200 V ac - Maximum: 240 V ac Heat output: Approximate heat output in British thermal units (Btu) per hour: v Minimum configuration: 1024 Btu/hour (300 watts) v Maximum configuration: 32757 Btu/hour (9600 watts) Airflow: Approximate airflow in cubic feet per minute (cfm): v Minimum airflow: 450 cfm v Maximum airflow: 975 cfm Notes: 1. Government regulations (such as those prescribed by Occupational Safety and Health Administration or European Community Directives) might govern noise level exposure in the workplace and might apply to you and your server installation. The actual sound pressure levels in your installation depend on a variety of factors, including the number of racks in the installation; the size, materials, and configuration of the room where you designate the racks to be installed; the noise levels from other equipment; the room ambient temperature; and employees' location in relation to the equipment. Compliance with such government regulations also depends on a variety of additional factors, including the duration of employees' exposure and whether employees wear hearing protection. It is recommended that you consult qualified experts in this field to determine whether you are in compliance with the applicable regulations. The BladeCenter modules The BladeCenter unit contains the following hot-swap modules: v Advanced management modules v I/O modules v Power modules v Blower modules Chapter 1. Introduction 3