IBM 88743RU User Guide - Page 59

Completing, installation

Page 59 highlights

a. Make sure that the microprocessor-tray release latch is open; then, push the microprocessor tray into the server. b. Close the tray levers and make sure that they are securely latched. c. Press the microprocessor-tray release latch down. d. Reinstall the fans and memory cards in the server. If you have other options to install or remove, do so now; otherwise, go to "Completing the installation." Completing the installation To complete the installation, complete the following steps: 1. If you removed the server cover, place the cover-release latch in the open (up) position. Insert the bottom tabs of the top cover into the matching slots in the server chassis. Press down on the cover-release latch to lock the cover in place. Replace the bezel, if you removed it. Top cover Bezel Cover release latch 2. Install the server in a rack. See the Rack Installation Instructions that come with the server for complete rack installation and removal instructions. Attention: v Install the server only in a rack cabinet with perforated doors. v Do not leave open spaces above or below an installed server in the rack cabinet. To help prevent damage to server components, always install a blank filler panel to cover the open space and to help ensure proper air circulation. See the documentation that comes with your rack cabinet for more information. 3. Connect the cables and power cords. See "Connecting the cables" on page 48 for more information. Chapter 2. Installing options 47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

a.
Make
sure
that
the
microprocessor-tray
release
latch
is
open;
then,
push
the
microprocessor
tray
into
the
server.
b.
Close
the
tray
levers
and
make
sure
that
they
are
securely
latched.
c.
Press
the
microprocessor-tray
release
latch
down.
d.
Reinstall
the
fans
and
memory
cards
in
the
server.
If
you
have
other
options
to
install
or
remove,
do
so
now;
otherwise,
go
to
“Completing
the
installation.”
Completing
the
installation
To
complete
the
installation,
complete
the
following
steps:
1.
If
you
removed
the
server
cover,
place
the
cover-release
latch
in
the
open
(up)
position.
Insert
the
bottom
tabs
of
the
top
cover
into
the
matching
slots
in
the
server
chassis.
Press
down
on
the
cover-release
latch
to
lock
the
cover
in
place.
Replace
the
bezel,
if
you
removed
it.
Bezel
Top cover
Cover release
latch
2.
Install
the
server
in
a
rack.
See
the
Rack
Installation
Instructions
that
come
with
the
server
for
complete
rack
installation
and
removal
instructions.
Attention:
v
Install
the
server
only
in
a
rack
cabinet
with
perforated
doors.
v
Do
not
leave
open
spaces
above
or
below
an
installed
server
in
the
rack
cabinet.
To
help
prevent
damage
to
server
components,
always
install
a
blank
filler
panel
to
cover
the
open
space
and
to
help
ensure
proper
air
circulation.
See
the
documentation
that
comes
with
your
rack
cabinet
for
more
information.
3.
Connect
the
cables
and
power
cords.
See
“Connecting
the
cables”
on
page
48
for
more
information.
Chapter
2.
Installing
options
47