Icom IC-V3500 Advanced Manual - Page 13

Reversed Duplex function, Auto Repeater function, Setting the Auto Repeater function ON/OFF

Page 13 highlights

2. REPEATER OPERATION Reversed Duplex function When the Reversed Duplex function is ON, the receive frequency shifts. (The transmit frequency shifts in normal Duplex mode.) An example receive and transmit frequency are shown in the table below with the following settings: Input frequency: 145.30 MHz Offset direction: - (Negative) Offset frequency: 0.6 MHz Function RX frequency TX frequency OFF 145.30 MHz 144.70 MHz ON 144.70 MHz 145.30 MHz 1. Push [SET LOCK] to enter the Set mode. 2. Repeatedly push [SET LOCK] or [MONI ANM PA] to select "REV" (Reverse mode). 3. Rotate [DIAL] to turn the function ON or OFF. 4. Push any key other than [SET LOCK] or [MONI ANM PA] to save and exit the Set mode. Using the HM-133V 1. Push [SET B D-OFF] to enter the Set mode. 2. Repeatedly push [SET B D-OFF] or [ENT C T-OFF] to select "REV." 3. Push [▲] or [▼] to turn the function ON or OFF. 4. Push [CLR A MW] to save and exit the Set mode. MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY The Reversed mode item MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz The duplex icon blinks when the function is ON. Auto Repeater function NOTE: This function is only for the USA version. The USA version automatically activates the repeater settings (DUP- or DUP+ and tone encoder ON/OFF) when the operating frequency falls within the general repeater output frequency range and deactivates them when outside of the range. DDSetting the Auto Repeater function ON/OFF 1. Push [ ] to turn OFF the transceiver. 2. While holding down [SET LOCK], hold down [ ] for 1 second to enter the Initial Set mode. 3. Repeatedly push [SET LOCK] or [MONI ANM PA] to select "RPT" (Auto Repeater). 4. Rotate [DIAL] to select an option from "R1," "R2," or "OF." •• "OF": The function is OFF. •• "R1": The function is ON, but the tone encoder is OFF. •• "R2": Both the function and tone encoder are ON. 5. Push [ ] to exit the Initial Set mode. DDFrequency range and offset direction Frequency range 145.200 ~ 145.495 MHz 146.610 ~ 146.995 MHz 147.000 ~ 147.395 MHz Duplex direction A "-" is displayed. A "-" is displayed. A "+" is displayed. MUTE NAR MID LOW LOCK SET ANM MONI DUP LOW DIGITAL PRIO AO BUSY T-SCAN TONE PRIO M/CALL SCAN V/ MHz MUTE NAR MID LOW LOCK SET ANM MONI DIGITAL PRIO AO BUSY DUP LOW T-SCAN TONE PRIO M/CALL SCAN V/ MHz The Auto Repeater item 2-5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89

2-5
2.
REPEATER OPERATION
When the Reversed Duplex function is ON, the
receive frequency shifts± (The transmit frequency
shifts in normal Duplex mode±) An example receive
and transmit frequency are shown in the table below
with the following settings:
Input frequency:
145±30 MHz
Offset direction:
– (Negative)
Offset frequency: 0±6 MHz
Function
OFF
ON
RX frequency
145±30 MHz
144±70 MHz
TX frequency
144±70 MHz
145±30 MHz
Push [SET LOCK] to enter the Set mode±
Repeatedly push [SET LOCK] or [MONI ANM PA]
to select “REV” (Reverse mode)±
Rotate [DIAL] to turn the function ON or OFF±
Push any key other than [SET LOCK] or
[MONI ANM PA] to save and exit the Set mode±
Using the HM-133V
Push [SET B D-OFF] to enter the Set mode±
Repeatedly push [SET B D-OFF] or
[ENT C T-OFF] to select “REV±”
Push [▲] or [▼] to turn the function ON or OFF.
Push [CLR A MW] to save and exit the Set mode±
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
LOCK
S
E
T
ANM
MONI
DUP
LOW
T-SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW
The duplex icon blinks
when the function is ON±
The Auto Repeater item
Reversed Duplex function
Auto Repeater function
NOTE:
This function is only for the USA version±
The USA version automatically activates the repeater
settings (DUP– or DUP+ and tone encoder ON/OFF)
when the operating frequency falls within the general
repeater output frequency range and deactivates them
when outside of the range±
D
Setting the Auto Repeater function
ON/OFF
1± Push [
] to turn OFF the transceiver±
While holding down [SET LOCK], hold down [
]
for 1 second to enter the Initial Set mode±
Repeatedly push [SET LOCK] or [MONI ANM PA]
to select “RPT” (Auto Repeater)±
Rotate [DIAL] to select an option from “R1,” “R2,”
or “OF±”
“OF”: The function is OFF±
• “R1”:
The function is ON, but the tone encoder
is OFF±
• “R2”:
Both the function and tone encoder are
ON±
5± Push [
] to exit the Initial Set mode±
D
Frequency range and offset direction
Frequency range
Duplex direction
145±200 ~ 145±495 MHz
A “-” is displayed±
146±610 ~ 146±995 MHz
A “-” is displayed±
147±000 ~ 147±395 MHz
A “+” is displayed±
The Reversed mode item
LOCK
S
E
T
ANM
MONI
DIGITAL PRIO AO BUSY
MUTE
NAR
MID
LOW