Intel® Server Board S1200BT TPS Appendix B: Integrated BMC Sensor Tables Table 57. BMC Core Sensors Full Sensor Name (Sensor name in SDR) Power Unit Status (Pwr Unit Status) Sensor # Platform Applicability Sensor Type 01h All Power Unit 09h Event/Reading Type Sensor Specific 6Fh Event Offset Triggers 00 - Power down 04 - A/C lost 05 - Soft power control failure Contrib. To System Status OK Fatal Assert/Deassert As and De Readable Event Data Value/Offse ts - Trig Offset 06 - Power unit failure 00 - Fully Redundant OK Rearm Stand-by A X 01 - Redundancy lost Degraded Power Unit Redundancy1 02h Chassisspecific (Pwr Unit Redund) Power Unit 09h Generic 0Bh 02 - Redundancy degraded 03 - Non-redundant: sufficient resources. Transition from full redundant state. 04 - Non-redundant: sufficient resources. Transition from insufficient state. 05 - Non-redundant: insufficient resources 06 - Redundant: degraded from fully redundant state. 07 - Redundant: Transition from nonredundant state. Degraded Degraded Degraded Fatal Degraded Degraded As and De - Trig Offset A X IPMI Watchdog (IPMI Watchdog) 03h All Watchdog 2 Sensor Specific 23h 6Fh 00 - Timer expired, status only 01 - Hard reset OK Trig As - Offset A X Revision 2.0 133 Intel order number G13326-004