Intel S1200BT Technical Product Specification - Page 151
Sensor Type
![]() |
View all Intel S1200BT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 151 highlights
Intel® Server Board S1200BT TPS Appendix B: Integrated BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Status (HDD 1 Status) Hard Disk Drive 2 Status (HDD 2 Status) Hard Disk Drive 3 Status (HDD 3 Status) Sensor # Platform Applicability Sensor Type specific 0Dh F2h Chassisspecific Drive Slot 0Dh F3h Chassisspecific Drive Slot 0Dh Event/Reading Type 6Fh Sensor Specific 6Fh Sensor Specific 6Fh Event Offset Triggers 01- Drive Fault 02- Predictive Failure 07 - Rebuild/Remap in progress 00 - Drive Presence 01- Drive Fault 02- Predictive Failure 07 - Rebuild/Remap in progress 00 - Drive Presence 01- Drive Fault 02- Predictive Failure 07 - Rebuild/Remap in progress Contrib. To System Status Degraded Degraded Degraded OK Degraded Degraded Degraded OK Degraded Degraded Degraded Assert/Deassert De As and De As and De Readable Value/Offse ts Event Data Offset - Trig Offset - Trig Offset Rearm Stand-by A X A Revision 2.0 139 Intel order number G13326-004
![](/manual_guide/products/intel-s1200bt-technical-product-specification-079ab15/151.png)