Intermec CN50 CN50 Mobile Computer for Windows Embedded Handheld 6.5 User Manu - Page 127
EA21 Area Imager Minimum Reading Distances
View all Intermec CN50 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 127 highlights
Appendix A - Specifications and Default Settings EA21 Area Imager Minimum Reading Distances Minimum distances are measured in the dark (0 lux). 0" in 16" 4" 8" 12" 16" 20" 24" 28" 32" 40 12" 30 PDF417 10 mils 8" Data Matrix 10 mils 20 4" 10 0" 0 4" 10 0.15mm/6 mils 8" 20 0.25 mm / 10 mils 12" 30 100% contrast UPC EAN 16" 0.5 mm / 20 mils 40 cm 0 10 20 30 40 50 60 70 80 EA21 Minimum Reading Distances Symbology Code 39 UPC/EAN 100% Data Matrix Density 0.15 mm (6.0 mil) 0.25 mm (10.0 mil) 0.5 mm (20.0 mil) 1.0 mm (40.0 mil) 0.33 mm (13.0 mil) 0.25 mm (10.0 mil) 0.38 mm (15.0 mil) Minimum Distance 12.0 cm (4.7 in) 5.0 cm (2.0 in) 5.0 cm (2.0 in) 9.0 cm (3.5 in) 5 cm (2 in) 12 cm (4.7 in) 8.0 cm (3.15 in) Maximum Distance 18.0 cm (7.1 in) 30.0 cm (11.8 in) 60 cm (23.6 in) 95 cm (37.4 in) 38.0 cm (15.0 in) 22 cm (8.7 in) 34 cm (13.4 in) CN50 Mobile Computer for Windows Embedded Handheld 6.5 User Manual 113