Intermec PX4i Intermec Direct Protocol 8.60 Programmer's Reference Manual - Page 23

Syntax Descriptions

Page 23 highlights

Chapter 2-Principles of Operation 2.14 Syntax Descriptions Many commonly used instructions have a shorthand version to minimize the transfer of data. In the explanations of the various instruction that follow, both the full name and the shorthand version will be shown, separated by a thin vertical line, for example: PRPOS | PP Unless otherwise indicated, upper- and lowercase characters can be used at will. Parameters for the instruction are shown like this: "" = numeric value = alphanumeric text (enclosed by quotation marks) • Compulsory space characters are indicated by double-headed arrows ( ↔ ). • Square brackets [ ] indicate optional parameters. • Vertical bars (|) separate alternatives. • Always enter parentheses, commas, colons, semicolons, minus signs, quotation marks, and period characters exactly as shown. • Negative values are indicated by leading minus signs (-). The various instructions are described in as simple terms as possible. Complete syntax descriptions and comprehensive information on each instruction can be found in the Intermec Fingerprint v.8.60, Programmer's Reference Manual. Intermec Direct Protocol v.8.60-Programmer's Reference Manual 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134

Intermec Direct Protocol v.8.60—Programmer’s Reference Manual
15
Chapter 2—Principles of Operation
2.14 Syntax Descriptions
Many commonly used instructions have a shorthand version to mini-
mize the transfer of data. In the explanations of the various instruction
that follow, both the full name and the shorthand version will be shown,
separated by a thin vertical line, for example:
PRPOS | PP
Unless otherwise indicated, upper- and lowercase characters can be used
at will. Parameters for the instruction are shown like this:
<parameter>
=
numeric value
"<parameter>"
=
alphanumeric text (enclosed by quotation marks)
Compulsory space characters are indicated by double-headed arrows
(
).
• Square brackets [
] indicate optional parameters.
• Vertical bars (|) separate alternatives.
Always enter parentheses, commas, colons, semicolons, minus signs,
quotation marks, and period characters exactly as shown.
Negative values are indicated by leading minus signs (-).
°e various instructions are described in as simple terms as possible.
Complete syntax descriptions and comprehensive information on each
instruction can be found in the
Intermec Fingerprint v.8.60, Programmer’s
Reference Manual
.