Invacare IFX-20MP Owners Manual - Page 11

Pinch Points, 2.3 Footplates and Front Rigging, WARNING, Risk of Injury or Damage

Page 11 highlights

WARNING! Risk of Injury or Damage Erratic or unintended movement of the wheelchair may occur if wireless transmitters are connected to the wheelchair. To avoid injury or damage: -DO NOT use the USB charger connector as a wireless transmitter. -The USB Port is NOT intended for communication purposes or to upload information to the device. -Only use the USB charger for the purposes described in the remote manual. 2.2 Pinch Points WARNING! Risk of Minor to Serious Injury Pinch points can cause minor to serious injury. -Be mindful of potential pinch points and use caution when using this product. WARNING! Risk of Injury Pinch points can cause injury. -Be aware that a pinch point A exists between the head tube cap and rear swingarm. -Be aware that a pinch point C may occur when rotating the center mount front rigging assembly. 2 Safety Fig. 2-1 Pinch Points - Head Tube Cap/Walking Beam and Telescoping Tube Fig. 2-2 Pinch Points - Center Mount Front Rigging 2.3 Footplates and Front Rigging WARNING! Risk of Serious Injury or Damage Operating the wheelchair with a clearance of less than 75 mm (3 inches) between the footplates and the ground/floor may cause serious injury or property damage. -ALWAYS maintain a minimum of 75 mm (3 inches) 60101916-A 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

WARNING!
Risk of Injury or Damage
Erratic or unintended movement of the wheelchair
may occur if wireless transmitters are connected to
the wheelchair. To avoid injury or damage:
-DO NOT use the USB charger connector as a wireless
transmitter.
-The USB Port is NOT intended for communication
purposes or to upload information to the device.
-Only use the USB charger for the purposes described
in the remote manual.
2.2 Pinch Points
WARNING!
Risk of Minor to Serious Injury
Pinch points can cause minor to serious injury.
-Be mindful of potential pinch points and use caution
when using this product.
WARNING!
Risk of Injury
Pinch points can cause injury.
-Be aware that a pinch point
A
exists between
the
head tube cap and rear swingarm.
-Be aware that a pinch point
C
may occur when
rotating the center mount front rigging assembly.
Fig. 2-1 Pinch Points — Head Tube Cap/Walking Beam and
Telescoping
Tube
Fig. 2-2 Pinch Points — Center Mount Front Rigging
2.3 Footplates and Front Rigging
WARNING!
Risk of Serious Injury or Damage
Operating the wheelchair with a clearance of
less than
75 mm (3 inches) between the
footplates and the ground/floor may cause
serious injury or property damage.
-ALWAYS maintain a minimum of 75 mm (3 inches)
60101916-A
11
2 Safety