Lacie 131018 User Manual - Page 160
Controller Events Messages, Type [ID], Cause, Action
UPC - 093053789114
View all Lacie 131018 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 160 highlights
StorView RAID Module Controller Events Messages Type [ID] Cause Action The onboard cache protection Error Battery failure. battery backup unit has failed [0xB07 (2823)] or has been disconnected. Replace battery in the controller. The partner controller has failed or has been removed. Error [0xB08 (2824)] Failure or removal of one controller (partner) in an Active-Active configuration. Re-install the controller. or Replace the controller. This controller has not received a response from the other (partner) controller in the allotted time, and therefore it has been disabled. Error [0xB09 (2825)] Failure or removal of one controller (partner) in an Active-Active configuration. Replace the controller. An error has been detected on the SAS domain or with a SAS device during the discovery process. Error [0xB0F (2831)] Possible drive or internal bus error. Replace drive. The controller's voltage reading measures V which exceeds the limit. Error [0xB19 (2841)] Voltage regulator hardware failure. Enclosure 5V or 12V problem in the power supply. Replace the controller. Replace the defective Power Supply or Power Supply/Cooling module. Internal transfer error. Error Hardware problem. [0xB1A (2842)] Replace the controller. Controller mismatch detected. "This" or "The other" controller was shut down. Error [0xB1C (2844)] RAID Controllers with different SAS controller chips have been installed. This is not a supported configuration. Replace one of the controllers so that both controllers are of the same type. For example all F5402E RAID Controllers or all F5412E RAID Controllers. The other (partner) controller Information Partner controller has has been inserted. [0xB29 (2857)] been inserted. No action necessary. The other (partner) controller Information Partner controller is ready No action necessary. has passed its self-test and is [0xB2A (2858)] to fail back. now ready (failback). A stripe synchronization of a RAID set has started. This occurs when a controller fails, or after a controller is powered off with write commands in progress. Information [0xB2C (2860)] A controller fails or is powered off during a write operation. No action necessary. 152