Lenovo ThinkPad X40 User Manual - Page 72

Error, messages

Page 72 highlights

Symptom-to-FRU index Error messages Symptom or error Device address conflict. Allocation error for device. Failing bits: nnnn. Invalid system configuration data. I/O device IRQ conflict. Operating system not found. Hibernation error. Fan error. Thermal sensing error. Authentication of system services failed. Press to resume. CD ROM drive Entering SETUP FRU or action, in sequence 1. Load "Setup Defaults" in BIOS Setup Utility. 2. Backup battery. 3. System board. 1. Load "Setup Defaults" in BIOS Setup Utility. 2. Backup battery. 3. System board. 1. DIMM. 2. System board. 1. DIMM. 2. System board. 1. Load "Setup Defaults" in BIOS Setup Utility. 2. Backup battery. 3. System board. 1. Check that the operating system has no failure and is installed correctly. 2. Enter BIOS Setup Utility and see whether the hard disk drive and the diskette drive are properly identified. 3. Reseat the hard disk drive. 4. Reinstall the operating system. 5. Diskette drive. 6. Hard disk drive. 7. System board. 1. Restore the system configuration to what it was before the computer entered hibernation mode. 2. If memory size has been changed, re-create the hibernation file. Fan. System board. The Predesktop Area in the hard disk drive is corrupted. Restore it from a recovery CD. 1. DIMM. 2. System board. 1. DIMM. 2. System board. (continued) 68 MT 2369/2370/2371/2372/2382/2386

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152

Error
messages
Symptom
or
error
FRU
or
action,
in
sequence
Device
address
conflict.
1.
Load
“Setup
Defaults”
in
BIOS
Setup
Utility
.
2.
Backup
battery.
3.
System
board.
Allocation
error
for
device.
1.
Load
“Setup
Defaults”
in
BIOS
Setup
Utility
.
2.
Backup
battery.
3.
System
board.
Failing
bits:
nnnn.
1.
DIMM
.
2.
System
board.
Invalid
system
configuration
data.
1.
DIMM
.
2.
System
board.
I/O
device
IRQ
conflict.
1.
Load
“Setup
Defaults”
in
BIOS
Setup
Utility
.
2.
Backup
battery.
3.
System
board.
Operating
system
not
found.
1.
Check
that
the
operating
system
has
no
failure
and
is
installed
correctly.
2.
Enter
BIOS
Setup
Utility
and
see
whether
the
hard
disk
drive
and
the
diskette
drive
are
properly
identified
.
3.
Reseat
the
hard
disk
drive.
4.
Reinstall
the
operating
system.
5.
Diskette
drive.
6.
Hard
disk
drive.
7.
System
board.
Hibernation
error.
1.
Restore
the
system
configuration
to
what
it
was
before
the
computer
entered
hibernation
mode
.
2.
If
memory
size
has
been
changed,
re-create
the
hibernation
file.
Fan
error.
Fan
.
Thermal
sensing
error.
System
board
.
Authentication
of
system
services
failed.
Press
<Esc>
to
resume.
The
Predesktop
Area
in
the
hard
disk
drive
is
corrupted.
Restore
it
from
a
recovery
CD.
CD
ROM
drive
1.
DIMM
.
2.
System
board.
Entering
SETUP
1.
DIMM
.
2.
System
board.
(continued)
Symptom-to-FRU
index
68
MT
2369/2370/2371/2372/2382/2386