LiftMaster LA400DC LA400DC Owner's Manual - Page 28

Programming, Remote Controls (not Provided)

Page 28 highlights

PROGRAMMING REMOTE CONTROLS (NOT PROVIDED) A total of 50 Security✚ 2.0™ remote controls and 2 keyless entries (1 PIN for each keyless entry) can be programmed to the operator. When programming a third keyless entry to the operator, the first keyless entry will be erased to allow the third keyless entry to be programmed. When the operator's memory is full it will exit the programming mode and the remote control will not be programmed. The memory will need to be erased before programming any additional remote controls. NOTE: If installing an 86LM to extend the range of the remote controls DO NOT straighten the antenna. There are 3 different options for programming the remote control depending on how you would like the remote control to function. Choose a programming option: LEARN T BUT XMITTER NETWORK REVERSAL FORCE XMITTER TEST BUTTONS NETWORK RSAL RCE OPEN CLOSE STOP OPTION Single button as OPEN only Single button (SBC) as OPEN, CLOSE, and STOP Three separate buttons as OPEN, CLOSE, and STOP DESCRIPTION PROGRAMMING STEPS Program a single button on the remote control for open only. The Timer-to-Close can be set to close the gate. Program one remote control button as an open, close, and stop. 1. Press and release the LEARN button (operator will beep and green XMITTER LED will light). 2. Press the OPEN button. 3. Press the remote control button that you would like to program. 1. Press and release the LEARN button (operator will beep and green XMITTER LED will light). 2. Press the remote control button that you would like to program. Program each remote control button 1. Press and release the LEARN button (operator will beep and green XMITTER as an open, close, and stop. LED will light). 2. Press the OPEN, CLOSE, or STOP button, depending on the desired function. 3. Press the remote control button that you would like to program. The operator will automatically exit learn mode (operator will beep and green XMITTER LED will go out) if programming is successful. To program additional Security✚ 2.0™ remote controls or remote control buttons, repeat the programming steps above. NOTICE: To comply with FCC and/or Industry Canada (IC) rules, adjustment or modifications of this transceiver are prohibited. THERE ARE NO USER SERVICEABLE PARTS. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC rules and IC RSS-210. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003. 26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

26
OPEN
CLOSE
STOP
TEST
BUTTONS
RSAL
RCE
XMITTER
NETWORK
LEARN
T
BUT
REVERSAL
FORCE
XMITTER
NETWORK
REMOTE CONTROLS (NOT PROVIDED)
A total of 50 Security
2.0™ remote controls and 2 keyless entries (1
PIN for each keyless entry) can be programmed to the operator. When
programming a third keyless entry to the operator, the first keyless entry
will be erased to allow the third keyless entry to be programmed. When
the operator’s memory is full it will exit the programming mode and the
remote control will not be programmed. The memory will need to be
erased before programming any additional remote controls.
NOTE:
If
installing an 86LM to extend the range of the remote controls DO NOT
straighten the antenna.
There are 3 different options for programming the remote control
depending on how you would like the remote control to function.
Choose a programming option:
OPTION
DESCRIPTION
PROGRAMMING STEPS
Single button as OPEN
only
Program a single button on the
remote control for open only. The
Timer-to-Close can be set to close
the gate.
1.
Press and release the LEARN button (operator will beep and green XMITTER
LED will light).
2.
Press the OPEN button.
3.
Press the remote control button that you would like to program.
Single button (SBC) as
OPEN, CLOSE, and
STOP
Program one remote control button
as an open, close, and stop.
1.
Press and release the LEARN button (operator will beep and green XMITTER
LED will light).
2.
Press the remote control button that you would like to program.
Three separate buttons
as OPEN, CLOSE, and
STOP
Program each remote control button
as an open, close, and stop.
1.
Press and release the LEARN button (operator will beep and green XMITTER
LED will light).
2.
Press the OPEN, CLOSE, or STOP button, depending on the desired function.
3.
Press the remote control button that you would like to program.
The operator will automatically exit learn mode (operator will beep and
green XMITTER LED will go out) if programming is successful. To
program additional Security
2.0™ remote controls or remote control
buttons, repeat the programming steps above.
PROGRAMMING
NOTICE: To comply with FCC and/or Industry Canada (IC) rules, adjustment or modifications of this
transceiver are prohibited. THERE ARE NO USER SERVICEABLE PARTS. Any changes or modifications not
expressly approved by the party responsible for compliance could void the user’s authority to operate the
equipment.
This device complies with Part 15 of the FCC rules and IC RSS-210. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
This Class B digital apparatus complies with Canadian ICES-003.