OPERATION MANUAL RELEASE In case of a power failure, the operator can be disengaged from the gate. With an operator, the release action may sometimes feel stiff/jerky, which is normal and has no effect on function. NOTE: It is normal for the operator to run slow right after a disconnect or complete loss of AC/ battery power (the operator will need to run a complete open and close cycle). RELEASE 1. Insert the key into the lock. 2. Turn the key counter-clockwise 180°. 3. Turn the release lever counter-clockwise 180°. Operator is in manual mode and the gate can be opened and closed manually. ENGAGE 1. Turn the release lever clockwise 180°. This engages the motor. 2. Turn the key clockwise 180°. This locks the release lever. 3. Remove the key and store in a safe place. The operator is now engaged. RESET BUTTON The reset button is located on the side of the control box and serves several functions: • Press the reset button to stop a moving gate during a normal open/ close cycle, like a stop button. • Press the reset button once while the gate is in open position to disable the Timer-to-Close. The gate will stay in the open position. To restart the Timer-to-Close either press the reset button or activate the gate with a programmed remote control. • Press the reset button to shut off the alarm and reset the operator. PARTY MODE Press the reset button once while the gate is in open position to disable the Timer-to-Close. The gate will stay in the open position. To restart the Timer-to-Close either press the reset button or activate the gate with a programmed remote control. 29 Reset Button

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

29
MANUAL RELEASE
In case of a power failure, the operator can be disengaged from the gate.
With an operator, the release action may sometimes feel stiff/jerky, which
is normal and has no effect on function.
NOTE:
It is normal for the
operator to run slow right after a disconnect or complete loss of AC/
battery power (the operator will need to run a complete open and close
cycle).
RELEASE
1.
Insert the key into the lock.
2.
Turn the key counter-clockwise 180°.
3. Turn the release lever counter-clockwise 180°.
Operator is in manual mode and the gate can be opened and closed
manually.
ENGAGE
1.
Turn the release lever clockwise 180°. This engages the motor.
2.
Turn the key clockwise 180°. This locks the release lever.
3.
Remove the key and store in a safe place. The operator is now
engaged.
RESET BUTTON
The reset button is located on the side of the control box and serves
several functions:
Press the reset button to stop a moving gate during a normal open/
close cycle, like a stop button.
Press the reset button once while the gate is in open position to
disable the Timer-to-Close. The gate will stay in the open position. To
restart the Timer-to-Close either press the reset button or activate the
gate with a programmed remote control.
Press the reset button to shut off the alarm and reset the operator.
PARTY MODE
Press the reset button once while the gate is in open position to disable
the Timer-to-Close. The gate will stay in the open position. To restart the
Timer-to-Close either press the reset button or activate the gate with a
programmed remote control.
OPERATION
Reset Button