ACCESSORY WIRING LOCKS MAGLOCK (2 Terminals, N.C. and COM) Relay contact output, Normally - closed (N.C.) output for maglocks. Relay activates prior to motor activation and during motor run. Relay is off when motor is off. NOTE: For AC power install a Siemens S10K30 MOV (Metal Oxide Varistor) or equivalent. For DC power install a 1N4005 diode or equivalent. SOLENOID (2 Terminals, N.O. and COM) Normally - open (N.O.) output for solenoid locks Relay activates prior to motor activation and during motor run. Relay is off when motor is off. NOTE: For AC power install a Siemens S10K30 MOV (Metal Oxide Varistor) or equivalent. For DC power install a 1N4005 diode or equivalent. (control board) Maglock (control board) 1N4005 diode or equivalent. Siemens S10K30 MOV (Metal Oxide Varistor) or equivalent. - + (not provided) Solenoid Lock MISCELLANEOUS WIRING SINGLE BUTTON CONTROL (SBC) (2 Terminals) Gate command sequence - Open, Stop, Close, Stop,... Soft open (maintained switch does not override external safeties and does not reset alarm condition). FIRE DEPARTMENT OPEN INPUT (2 Terminals) Acts as hard open. Maintained input overrides (ignores) external safeties (photoelectric sensor and edge), pauses Timer-to-Close momentary input logic as single button control and safeties remain active, re-enables Timer-to-Close. ACCESSORY POWER 24 VDC, MAX 500 mA (4 Terminals) • SWITCHED: Switched ON with gate motion (stays on 5 seconds after motion). • UNSWITCHED: 24 Vdc voltage out to power accessories, always ON. 1N4005 diode or equivalent. - + (not provided) (main control board) Single Button Control Station SBC Com Fire Dept Com Fire Department (main control board) Accessory Power Switched Com (-) Acc Power +24 Vdc Com (-) Acc Power +24 Vdc Accessory Power Unswitched 32

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

32
LOCKS
MAGLOCK
(2 Terminals, N.C. and COM)
Relay contact output, Normally - closed (N.C.) output for maglocks.
Relay activates prior to motor activation and during motor run. Relay is
off when motor is off.
NOTE:
For AC power install a Siemens S10K30 MOV (Metal Oxide
Varistor) or equivalent. For DC power install a 1N4005 diode or
equivalent.
SOLENOID
(2 Terminals, N.O. and COM)
Normally - open (N.O.) output for solenoid locks
Relay activates prior to motor activation and during motor run. Relay is
off when motor is off.
NOTE:
For AC power install a Siemens S10K30 MOV (Metal Oxide
Varistor) or equivalent. For DC power install a 1N4005 diode or
equivalent.
-
+
-
+
Siemens S10K30 MOV
(Metal Oxide Varistor)
or equivalent.
1N4005 diode
or equivalent.
1N4005 diode
or equivalent.
(control board)
(control board)
Maglock
Solenoid Lock
(not provided)
(not provided)
ACCESSORY WIRING
MISCELLANEOUS WIRING
SINGLE BUTTON CONTROL (SBC)
(2 Terminals)
Gate command sequence - Open, Stop, Close, Stop,...
Soft open (maintained switch does not override external safeties and does
not reset alarm condition).
FIRE DEPARTMENT OPEN INPUT
(2 Terminals)
Acts as hard open.
Maintained input overrides (ignores) external safeties (photoelectric
sensor and edge), pauses Timer-to-Close momentary input logic as single
button control and safeties remain active, re-enables Timer-to-Close.
ACCESSORY POWER 24 VDC, MAX 500 mA
(4 Terminals)
SWITCHED: Switched ON with gate motion (stays on 5 seconds after
motion).
UNSWITCHED: 24 Vdc voltage out to power accessories, always ON.
Com
SBC
(main control board)
Single Button Control Station
Fire Department
Com
Fire Dept
Acc Power +24 Vdc
Com (-)
(main control board)
Accessory Power Switched
Accessory Power Unswitched
Acc Power +24 Vdc
Com (-)