LiftMaster LA400DC LA400DC Owner's Manual - Page 8

SPECIFICATIONS, External Entrapment Protection Type B1 and/or Type B2

Page 8 highlights

INTRODUCTION SPECIFICATIONS This model is intended for use in vehicular swing gate applications: Usage Classification Main AC Supply System Operating Voltage Accessory Power Solar Power Max Maximum Gate Weight/Length 90 Degree Travel Time* Maximum Travel Range* Maximum Daily Cycle Rate Maximum Duty Cycle Operating Temperature Expansion Board Inherent Entrapment Protection (Type A) External Entrapment Protection (Type B1 and/or Type B2) Class I, II, & III 120 Vac, .5 Amps (6.5 Amps including Accessory Outlets) 24 Vdc Battery Run / Direct Plug-in Transformer Charge 24 Vdc, 500mA max. for ON + SW (switched) 24 Vdc at 60 watts max. 850 lbs. (385.6 kg) / 10 ft (3.0 m) 750 lbs. (340.2 kg) / 12 ft (3.7 m) 650 lbs. (294.8 kg) / 14 ft (4.3 m) 550 lbs. (249.5 kg) / 16 ft (4.9 m) 15-18 seconds 115 degrees 100 cycles / day 4 min on -20°C to 60°C (-4°F to 140°F) Optional Dual - RPM and Current Sense 3 inputs per board - any combination of up to 3 photoelectric sensors and up to 2 edge sensors *Travel time and range are affected by A and B mounting dimensions 4" (10.2 cm) 4-1/2" 1/4" (11.2 cm) (0.635 cm) 36-5/16" (92.2 cm) 1/2" DIA. (1.3 cm DIA.) 37-3/8" (94.9 cm) 53-1/2" (136 cm) Weight: 13.2 lbs. (6 kg.) Standard Control Box Large Metal Control Box 16-7/16" (41.8 cm) 20-3/4" (52.7 cm) 14-3/8" 6-9/16" (36.5 cm) (16.7 cm) 17-3/16" (43.7 cm) 6-3/16" (15.7 cm) 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

6
INTRODUCTION
Usage Classification
Class I, II, & III
Main AC Supply
120 Vac, .5 Amps (6.5 Amps including Accessory Outlets)
System Operating Voltage
24 Vdc Battery Run / Direct Plug-in Transformer Charge
Accessory Power
24 Vdc, 500mA max. for ON + SW (switched)
Solar Power Max
24 Vdc at 60 watts max.
Maximum Gate Weight/Length
850 lbs. (385.6 kg) / 10 ft (3.0 m)
750 lbs. (340.2 kg) / 12 ft (3.7 m)
650 lbs. (294.8 kg) / 14 ft (4.3 m)
550 lbs. (249.5 kg) / 16 ft (4.9 m)
90 Degree Travel Time*
15-18 seconds
Maximum Travel Range*
115 degrees
Maximum Daily Cycle Rate
100 cycles / day
Maximum Duty Cycle
4 min on
Operating Temperature
-20°C to 60°C (-4°F to 140°F)
Expansion Board
Optional
Inherent Entrapment Protection (Type A)
Dual - RPM and Current Sense
External Entrapment Protection (Type B1 and/or Type B2)
3 inputs per board - any combination of up to 3 photoelectric sensors and up to 2
edge sensors
*Travel time and range are affected by A and B mounting dimensions
SPECIFICATIONS
This model is intended for use in vehicular swing gate applications:
Weight: 13.2 lbs. (6 kg.)
36-5/16"
(92.2 cm)
1/2" DIA.
(1.3 cm DIA.)
4-1/2"
(11.2 cm)
1/4"
(0.635 cm)
37-3/8"
(94.9 cm)
53-1/2"
(136 cm)
4"
(10.2 cm)
Standard Control Box
16-7/16"
(41.8 cm)
14-3/8"
(36.5 cm)
Large Metal Control Box
6-9/16"
(16.7 cm)
20-3/4"
(52.7 cm)
17-3/16"
(43.7 cm)
6-3/16"
(15.7 cm)