SPECIFICATIONS, External Entrapment Protection Type B1 and/or Type B2
View all LiftMaster LA400DC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
INTRODUCTION SPECIFICATIONS This model is intended for use in vehicular swing gate applications: Usage Classification Main AC Supply System Operating Voltage Accessory Power Solar Power Max Maximum Gate Weight/Length 90 Degree Travel Time* Maximum Travel Range* Maximum Daily Cycle Rate Maximum Duty Cycle Operating Temperature Expansion Board Inherent Entrapment Protection (Type A) External Entrapment Protection (Type B1 and/or Type B2) Class I, II, & III 120 Vac, .5 Amps (6.5 Amps including Accessory Outlets) 24 Vdc Battery Run / Direct Plug-in Transformer Charge 24 Vdc, 500mA max. for ON + SW (switched) 24 Vdc at 60 watts max. 850 lbs. (385.6 kg) / 10 ft (3.0 m) 750 lbs. (340.2 kg) / 12 ft (3.7 m) 650 lbs. (294.8 kg) / 14 ft (4.3 m) 550 lbs. (249.5 kg) / 16 ft (4.9 m) 15-18 seconds 115 degrees 100 cycles / day 4 min on -20°C to 60°C (-4°F to 140°F) Optional Dual - RPM and Current Sense 3 inputs per board - any combination of up to 3 photoelectric sensors and up to 2 edge sensors *Travel time and range are affected by A and B mounting dimensions 4" (10.2 cm) 4-1/2" 1/4" (11.2 cm) (0.635 cm) 36-5/16" (92.2 cm) 1/2" DIA. (1.3 cm DIA.) 37-3/8" (94.9 cm) 53-1/2" (136 cm) Weight: 13.2 lbs. (6 kg.) Standard Control Box Large Metal Control Box 16-7/16" (41.8 cm) 20-3/4" (52.7 cm) 14-3/8" 6-9/16" (36.5 cm) (16.7 cm) 17-3/16" (43.7 cm) 6-3/16" (15.7 cm) 6