LiftMaster LA500 LA500 Manual - Page 13

Identify your installation type. The installation steps in this manual will show a typical Pull-to-Open application. - installation manual

Page 13 highlights

INSTALLATION TYPES Identify your installation type. The installation steps in this manual will show a typical Pull-to-Open application. PULL-TO-OPEN Column Install Post Install Gate Hinge Gate Hinge PUSH-TO-OPEN Column Install Gate Hinge SITE PREPARATION Post Install Gate Hinge Heavy Steel Plate for Reinforcement (Not provided) 10" Minimum Heavy Steel Bracket (Reinforce if necessary) Back Steel Bracket (Reinforce if necessary) Gate Hinge NOTE: Weld Re Bar Behind Gate Hinges for Maximum Strength. Top View Back Steel Plates for Reinforcement (Not provided) Heavy Steel Plate for Reinforcement (Not provided) Back Steel Bracket (Reinforce if necessary) Gate Hinge Gate Hinge NOTE: Weld Re Bar Behind Gate Hinges for Maximum Strength. Top View Heavy Steel Plate for Reinforcement (Not provided) Gate Hinge Control Box Operator SINGLE GATE ! Water Tight Conduit (Not provided) Earth Ground Rod Control Box Primary Operator ! DUAL GATE Secondary Operator Junction Box ! Water Tight Conduit (Not provided) Earth Ground Rod 11 Shielded low voltage wires.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

11
SITE PREPARATION
INSTALLATION TYPES
PULL-TO-OPEN
PUSH-TO-OPEN
Top View
Heavy Steel Plate for
Reinforcement (Not provided)
Back Steel Bracket
(Reinforce if necessary)
NOTE:
Weld Re Bar
Behind Gate Hinges for
Maximum Strength.
Gate Hinge
Top View
10"
Minimum
Heavy Steel
Bracket
(Reinforce if
necessary)
Back Steel Plates
for Reinforcement
(Not provided)
SINGLE GATE
!
!
!
DUAL GATE
Water Tight Conduit (Not provided)
Shielded low
voltage wires.
Earth Ground Rod
Primary Operator
Secondary Operator
Junction Box
Control Box
Control Box
Earth Ground Rod
Operator
Water Tight Conduit
(Not provided)
Identify your installation type. The installation steps in this manual will show a typical Pull-to-Open application.
Gate Hinge
Gate Hinge
Gate Hinge
Gate Hinge
Gate Hinge
Gate Hinge
Gate Hinge
Heavy Steel Plate
for Reinforcement
(Not provided)
Back Steel
Bracket
(Reinforce if
necessary)
Heavy Steel Plate
for Reinforcement
(Not provided)
Post Install
Column Install
Post Install
Column Install
NOTE:
Weld Re Bar
Behind Gate Hinges for
Maximum Strength.