ADJUSTMENT LIMIT AND FORCE ADJUSTMENT LIMIT AND FORCE ADJUSTMENT To reduce the risk of SEVERE INJURY or DEATH: • Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a moving gate. • Too much force on gate will interfere with proper operation of safety reversal system. • NEVER increase force beyond minimum amount required to move gate. • NEVER use force adjustments to compensate for a binding or sticking gate. • If one control (force or travel limits) is adjusted, the other control may also need adjustment. • After ANY adjustments are made, the safety reversal system MUST be tested. Gate MUST reverse on contact with a rigid object. INTRODUCTION Your operator is designed with electronic controls to make travel limit and force adjustments easy. The adjustments allow you to program where the gate will stop in the open and close position. The electronic controls sense the amount of force required to open and close the gate. The force is adjusted automatically when you program the limits but should be fine tuned using the REVERSAL FORCE dial on the control board (refer to Fine Tune the Force section) to compensate for environmental changes. The limits can be set using the control board (below) or a remote control (refer to Limit Setup with a Remote Control in the Additional Features section). Setting the limits with a remote control requires a 3-button remote control programmed to OPEN, CLOSE, and STOP. NOTE: The Test Buttons on the control board will not work until the limits have been set. SET OPEN LED BLINKING OFF BLINKING BLINKING ON ON LIMIT SETUP LEDS SET CLOSE OPERATOR MODE EXPLANATION LED BLINKING NORMAL MODE Limits are not set. OFF NORMAL MODE Limits are set. BLINKING LIMIT SETTING MODE Limits are not set. ON LIMIT SETTING MODE Open limit is not set. BLINKING LIMIT SETTING MODE Close limit is not set. ON LIMIT SETTING MODE Limits are set. INITIAL LIMITS AND FORCE ADJUSTMENT For dual gate applications the limits will have to be set for each operator. The gate MUST be attached to the operator before setting the limits and force. 1 1 Set the GATE switch to the 1 position. E PRESS & RELEASE 2 TI TO CL 3 TO BEGIN (SECOND SET OPEN SET CLOSE LIMIT 10 SETUP 1 P REL 2 Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode. 25 GATE OFF INPUT POWER TIM O MOVE GATE TO BE LIMI SETUP 1 2 GAT 3 Press and hold the MOVE GATE buttons to move the gate to the open or close limit. 4 Press and release the SET CLOSE or SET OPEN button depending on which limit is being set. SET OPEN SET CLOSE XM T ER NE WOR OPEN CLOSE STOP MOVE GATE R L AS T BE N MT SO ) 10 1 2 5 6 STATUS NPUT POWER BA T CHARG NG IMER ATE MOVI G B TT LOW ACC PWR OVL D AGNOST C CODES IRE D EX T S ADOW C OSE E INT RR J5 O J5 + INPU US 4 SET OPEN SET CLOSE BIP DEL OFF PRESS & RELEASE TO BE 5 Press and hold the MOVE GATE button to move the gate to the other limit. 6 Press and release the SET CLOSE or SET OPEN button depending on which limit is being set. 7 Cycle the gate open and close. This automatically sets the force. When limits are set properly the operator will automatically exit limit setting mode. ! CLOSE limit SW POWER A CESSORY + B TT + C OWER O N EXP BR RN WT YE LU ED BR RN WT E BLU ED SOL R / CHARG R + ROUND MOVE GATE SET OPEN SET CLOSE B DEL US OPEN limit PRESS & RELEASE TO BEG OFF 6 P REL TO BE LIMIT SETUP 1 5 2 GAT INPU DUAL GATES: Set the GATE switch to the 2 position and repeat steps 2-7 for the secondary gate. 25 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

25
OPEN limit
CLOSE limit
!
SET OPEN
SET CLOSE
MOVE
GATE
5
10
6
OPEN
CLOSE
STOP
NPUT POWER
BA
T CHARG NG
IMER
ATE MOVI
G
B
TT LOW
ACC PWR OVL
D AGNOST C
CODES
STATUS
IRE
D
EX T
S ADOW
C OSE
E
INT RR
O
A
CESSORY
POWER
ON
SW
EXP
XM T ER
NE
WOR
1
MT
2
+
J5
+
SOL
R /
CHARG R
J5
+
B TT
+
C
OWER
ROUND
BR
RN
WT
YE
LU
ED
BR
RN
WT
E
BLU
ED
SET OPEN
SET CLOSE
OFF
B
DEL
PRESS &
RELEASE
TO BEG
MOVE
GATE
INPU
US
P
REL
TO BE
SETUP
1
GAT
LIMIT
2
SET OPEN
SET CLOSE
OFF
BIP
DEL
PRESS &
RELEASE
TO BE
MOVE
GATE
INPU
US
P
REL
TO BE
SETUP
1
GAT
LIMI
2
SET OPEN
SET CLOSE
O
E
OFF
5
10
(SECOND
INPUT POWER
TIM
TI
TO CL
PRESS &
RELEASE
TO BEGIN
SETUP
1
GATE
LIMIT
2
3
1
2
4
5
LIMIT AND FORCE ADJUSTMENT
ADJUSTMENT
6
To reduce the risk of SEVERE INJURY or DEATH:
Without a properly installed safety reversal system, persons (particularly small
children) could be SERIOUSLY INJURED or KILLED by a moving gate.
Too much force on gate will interfere with proper operation of safety reversal
system.
NEVER increase force beyond minimum amount required to move gate.
NEVER use force adjustments to compensate for a binding or sticking gate.
If one control (force or travel limits) is adjusted, the other control may also
need adjustment.
After ANY adjustments are made, the safety reversal system MUST be tested.
Gate MUST reverse on contact with a rigid object.
LIMIT SETUP LEDS
SET OPEN
LED
SET CLOSE
LED
OPERATOR MODE
EXPLANATION
BLINKING
BLINKING
NORMAL MODE
Limits are not set.
OFF
OFF
NORMAL MODE
Limits are set.
BLINKING
BLINKING
LIMIT SETTING MODE
Limits are not set.
BLINKING
ON
LIMIT SETTING MODE
Open limit is not set.
ON
BLINKING
LIMIT SETTING MODE
Close limit is not set.
ON
ON
LIMIT SETTING MODE
Limits are set.
LIMIT AND FORCE ADJUSTMENT
INTRODUCTION
Your operator is designed with electronic controls to make travel limit and force
adjustments easy. The adjustments allow you to program where the gate will stop in
the open and close position. The electronic controls sense the amount of force
required to open and close the gate. The force is adjusted automatically when you
program the limits but should be fine tuned using the REVERSAL FORCE dial on the
control board (refer to Fine Tune the Force section) to compensate for environmental
changes.
The limits can be set using the control board (below) or a remote control (refer to
Limit Setup with a Remote Control in the Additional Features section). Setting the
limits with a remote control requires a 3-button remote control programmed to
OPEN, CLOSE, and STOP.
NOTE:
The Test Buttons on the control board will not work until the limits have been
set.
INITIAL LIMITS AND FORCE ADJUSTMENT
For dual gate applications the limits will have to be set for each
operator. The gate MUST be attached to the operator before setting the
limits and force.
1
Set the GATE switch to the 1 position.
2
Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter
limit setting mode.
3
Press and hold the MOVE GATE buttons to move the gate to the open or close
limit.
4
Press and release the SET CLOSE or SET OPEN button depending on which limit is
being set.
5
Press and hold the MOVE GATE button to move the gate to the other limit.
6
Press and release the SET CLOSE or SET OPEN button depending on which limit is
being set.
7
Cycle the gate open and close. This automatically sets the force.
When limits are set properly the operator will automatically exit limit setting mode.
DUAL GATES:
Set the GATE switch to the 2 position and repeat steps 2-7 for the
secondary gate.
7