LiftMaster LA500 LA500 Manual - Page 37
LIMIT SETUP WITH A REMOTE CONTROL, Set the Close Limit Only
View all LiftMaster LA500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
ADDITIONAL FEATURES LIMIT SETUP WITH A REMOTE CONTROL LIMIT SETUP WITH A REMOTE CONTROL To set the limits using a remote control, first you will need a 3-button remote control that has been programmed for OPEN, CLOSE, and STOP. Refer to the Programming section. NC NO + ON + W XP INITIAL LIMITS AND FORCE ADJUSTMENT For dual gate applications the limits will have to be set for each operator. The gate MUST be attached to the operator before setting the limits and force. Ensure the gate is closed. 1 Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode. 2 Press and hold the OPEN or CLOSE button on the remote control until the gate reaches the desired open position. The gate can be jogged back and forth using the OPEN and CLOSE buttons on the remote control. 3 Once the gate is in the desired open position, press and release the STOP button on the remote control. 4 Press and release the OPEN button on the remote control again to set the open limit. 5 Press and hold the CLOSE or OPEN button on the remote control until the gate reaches the desired close position. The gate can be jogged back and forth using the OPEN and CLOSE buttons on the remote control. 6 Once the gate is in the desired close position, press and release the STOP button on the remote control. 7 Press and release the CLOSE button on the remote control again to set the close limit. 8 Cycle the gate open and close. This automatically sets the force. When limits are set properly the operator will automatically exit limit setting mode. SET OPEN SET CLOSE B D FF SET OPEN SET CLOSE ER WO K MO E G TE STATUS R ES OB G LMT S C ND ) 10 2 5 OF N UT POW R TM R 6 0 MN MAX TT L W D AGN ST ODES IE D OP N SH DOW C OSE YE / I TER + 5 15 OC + AT + DC POW R POW R A CES ORY BR GRN WT E B U ED BR GRN WT YE B U RED S LAR / C ARG R + D ES T A A M 3-Button Remote Control programmed for OPEN, CLOSE, and STOP ADJUST THE LIMITS If the limits have already been set the operator will exit the limit setting mode after resetting each limit. Set the Close Limit Only Set the Open Limit Only 1 Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode. 1 Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode. 2 Press and hold the CLOSE button on the remote control until the gate reaches the desired close position. The gate can be jogged back and forth using the OPEN and CLOSE buttons on the remote control. 2 Press and hold the OPEN button on the remote control until the gate reaches the desired open position. The gate can be jogged back and forth using the OPEN and CLOSE buttons on the remote control. 3 3 Once the gate is in the desired close position, press and release the STOP button on the remote control. Once the gate is in the desired open position, press and release the STOP button on the remote control. 4 Press and release the CLOSE button on the remote control again to set the close limit. 4 Press and release the OPEN button on the remote control again to set the open limit. When the close limit is set properly the operator will automatically exit limit setting mode. When the open limit is set properly the operator will automatically exit limit setting mode. 35