Oki C942 C911dn/C931dn/C931DP/C941dn/C941DP/C942 Basic Users Guide - English - Page 33

Setting Up, Installing the Device, Installation Conditions

Page 33 highlights

Installing the Device Before use 2. Setting Up 1 This chapter explains the methods for setting up the device, and for connecting the device to a PC and installing the printer drivers. Note ⿟⿟Customers who have purchased C941/ES9541/Pro9541 should also see the "Separate Volume Spot Color Guide". Reference ⿟⿟See the "Fiery XF Sever Quick Start Guide" for the methods of setting up the color management server for models C931/C941/ 2 C942/ES9431/ES9541/ES9542/Pro9431/Pro9541/Pro9542. Setting Up ⿟⿟Installing the Device For safe and pleasant use of the device, install in a location that satisfied the "installation environment" and "installation space" described in the "installation conditions". Further, the conditions also describe the installation precautions. Make sure to read them before use. 3 Installation Conditions Consider the following environmental conditions before selecting the device installation location. „„Installation Environment Use in a location where temperature and humidity are within the following ranges. Ambient temperature: Ambient humidity: Max. wet-bulb temperature: 10ºC to 32ºC 20% to 80%RH (relative humidity) 25ºC Memo ⿟⿟Make sure there is no condensation. ⿟⿟If installing in a location where the ambient humidity is 30% or less, use a humidifier or static prevention mat. Printing „„Installation Space Make sure the area around the device has the following space, and select a location that can support the weight of the device before installing. (The main unit weights are as follows: C911/C931/ES9411/ES9431/Pro9431: Approx. 4 98kg*; C941/C942/ES9541/ES9542/Pro9541/ Pro9542: Approx. 111kg*.) *: Includes consumables such as image drums and toner cartridges, etc. Basic Device Operations zzPlane view 200mm 1770mm 620mm 460mm Appendix 1420mm zzFront view 600mm Index 400mm 1040mm - 33 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141

- 33 -
Installing the Device
Appendix
Printing
3
Setting Up
2
Before use
1
Basic Device Operations
4
Index
2. Setting Up
This chapter explains the methods for setting up the device, and for connecting the device to a PC and
installing the printer drivers.
Note
Customers who have purchased C941/ES9541/Pro9541 should also see the "Separate Volume
Spot Color Guide".
Reference
See the "Fiery XF Sever Quick Start Guide" for the methods of setting up the color management server for models C931/C941/
C942/ES9431/ES9541/ES9542/Pro9431/Pro9541/Pro9542.
Installing the Device
For safe and pleasant use of the device, install in a location that satisfied the "installation environment"
and "installation space" described in the "installation conditions". Further, the conditions also describe
the installation precautions. Make sure to read them before use.
Installation Conditions
Consider the following environmental conditions
before selecting the device installation location.
±
Installation Environment
Use in a location where temperature and
humidity are within the following ranges.
Ambient
temperature:
10ºC to 32ºC
Ambient
humidity:
20% to 80%RH (relative humidity)
Max. wet-bulb
temperature:
25ºC
Memo
Make sure there is no condensation.
If installing in a location where the ambient humidity is
30% or less, use a humidifier or static prevention mat.
±
Installation Space
Make sure the area around the device has
the following space, and select a location that
can support the weight of the device before
installing. (The main unit weights are as follows:
C911/C931/ES9411/ES9431/Pro9431: Approx.
98kg*; C941/C942/ES9541/ES9542/Pro9541/
Pro9542: Approx. 111kg*.)
*: Includes consumables such as image drums and toner
cartridges, etc.
z
Plane view
620mm
1420mm
600mm
460mm
200mm
1770mm
z
Front view
400mm
1040mm