Oki MC160MFP User Guide - Page 233
is uneven., be defective or low.
View all Oki MC160MFP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 233 highlights
Symptom Image is blurred; background is lightly stained; there is insufficient gloss of the printed image. Cause Solution One or more of the Remove the toner cartridges and toner cartridges may check for damage. If it is damaged, be defective. replace it. The imaging cartridge Remove the imaging cartridge and may be defective. check for damage. If it is damaged, replace it. The original glass is Clean the original glass. For details, dirty. refer to "Cleaning the Machine" on page 178. The original cover pad is dirty. Clean the original cover pad. For details, refer to "Cleaning the Machine" on page 178. The print or One or more of the Remove the toner cartridges and color density toner cartridges may check for damage. If it is damaged, is uneven. be defective or low. replace it. The imaging cartridge Remove the imaging cartridge and may be defective. check for damage. If it is damaged, replace it. The machine is not Place the machine on a flat, hard, level level. surface. Irregular print or mottled image appears. The media is moist from humidity. Adjust the humidity in the media storage area. Remove the moist media and replace it with new, dry media. Unsupported media (wrong size, thickness, type, etc.) is being used. Use Oki approved media. One or more of the Remove the toner cartridges and toner cartridges may check for damage. If it is damaged, be defective. replace it. The imaging cartridge Remove the imaging cartridge and may be defective. check for damage. If it is damaged, replace it. 233 Troubleshooting