Panasonic AG HPX170 Memory Card Camera Recorder - Page 112

OPTION MENU screen, Display, Description of settings, POWER SAVE, MENU INIT, OPERATION, FORMAT, SPEED

Page 112 highlights

Setup menu list (continued) OTHER FUNCTIONS screen (continued) Item POWER SAVE MENU INIT OPERATION Display mode (Camera) (Camera) (MCR) (Camera) (MCR) Description of settings Selects the power-saving mode when the Operation lever, MENU button, THUMBNAIL button, PAGE/AUDIO MON/VAR button, DISP/ MODE CHK button, USER1-3 buttons and EVF DTL button have not been operated for 5 minutes or so. ON: The camera-recorder's power is set to OFF. OFF: The unit remains stopped without turning off it's power. • When connection is made with an external device using the 1394 cable and the communication mode is established in this way, the power will not be set off even when none of the above buttons has been operated. • The power will not be turned off when a P2 card has not been installed, even if ON has been selected. Returns the menu settings to the factory settings. • The time zone setting will not be changed. Displays the power-on time (a 5-digit figure). OPTION MENU screen This menu is displayed when the DISP/MODE CHK button is held down, and after the details of the shooting status are displayed, the MENU button is then pressed.Use it to check the connection status during nonlinear editing. Item 1394 STATUS 1394 CONFIG Display mode (Camera) (MCR) (Camera) (MCR) Description of settings 1394 status display screen appears. FORMAT: Format of the signals which are input or output. RATE: Transfer rate of the signals which are input or output. 60/50: System of the signals which are input or output. CH: Value of the channels in which the signals are input or output. SPEED: Transfer speed of the signals which are input or output. STATUS: Status of the signals which are input or output using the 1394 digital interface. VIDEO: Status of the video signals which are input or output. AUDIO: Status of the audio signals which are input or output. 1394 extended menus appear. DFLT: Normally, DFLT is used. 1-255 112 ___indicates the factory setting.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

11±
Item
Display
mode
Description of settings
POWER SAVE
(Camera)
Selects the power-saving mode when the Operation lever, MENU
button, THUMBNAIL button, PAGE/AUDIO MON/VAR button, DISP/
MODE CHK button, USER1-3 buttons and EVF DTL button have not
been operated for 5 minutes or so.
ON:
The camera-recorder’s power is set to OFF.
OFF:
The unit remains stopped without turning off it’s power.
When connection is made with an external device using the 1394
cable and the communication mode is established in this way, the
power will not be set off even when none of the above buttons has
been operated.
The power will not be turned off when a P2 card has not been
installed, even if ON has been selected.
MENU INIT
(Camera)
(MCR)
Returns the menu settings to the factory settings.
The time zone setting will not be changed.
OPERATION
(Camera)
(MCR)
Displays the power-on time (a 5-digit figure).
OPTION MENU screen
This menu is displayed when the DISP/MODE CHK button is held down, and after the details of the
shooting status are displayed, the MENU button is then pressed.Use it to check the connection status
during nonlinear editing.
Item
Display
mode
Description of settings
1²9³ STATUS
(Camera)
(MCR)
1394 status display screen appears.
FORMAT:
Format of the signals which are input or output.
RATE:
Transfer rate of the signals which are input or output.
60/50:
System of the signals which are input or output.
CH:
Value of the channels in which the signals are input or output.
SPEED:
Transfer speed of the signals which are input or output.
STATUS:
Status of the signals which are input or output using the 1394
digital interface.
VIDEO:
Status of the video signals which are input or output.
AUDIO:
Status of the audio signals which are input or output.
1²9³ CONFIG
(Camera)
(MCR)
1394 extended menus appear.
DFLT:
Normally, DFLT is used.
1-255
Setup menu list (continued)
OTHER FUNCTIONS screen (continued)
___indicates the factory setting.