Panasonic KX-TDA600 Installation Manual - Page 166
With DPT - pabx
UPC - 037988851775
View all Panasonic KX-TDA600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 166 highlights
2.9 Connection of Extensions With DPT Parallel mode or eXtra Device Port (XDP) mode can be selected through system programming. If XDP mode is enabled through system programming, parallel connection is not possible. Refer to "1.13.2 Paralleled Telephone" and "1.5.7 Extension Port Configuration" in the Feature Manual for further information. Using a Modular T-Adaptor To DHLC8 card 4-conductor wiring cord Connect pins "D1" and "D2". Modular T-Adaptor 2-conductor wiring cord Connect pins "T" and "R". DPT Using an EXtra Device Port With KX-T7600 Series DPT To DHLC8 card 4-conductor wiring cord Connect pins "T", "R", "D1" and "D2". SLT 2-conductor wiring cord Connect pins "T" and "R". To DHLC8 card To SLT DPT SLT TO MAIN UNIT / PABX TO TEL 166 Installation Manual