Power Failure Connections
UPC - 037988851775
View all Panasonic KX-TDA600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 203 highlights
2.13 Power Failure Connections 2.13 Power Failure Connections 2.13.1 Power Failure Connections When the power supply to the Hybrid IP-PBX fails, power failure transfer (PFT) will switch from the current connection to the Power Failure Connection. Refer to "1.13.9 Power Failure Transfer" in the Feature Manual for further information. Connection Power Failure Connection connects a specific SLT and a CO line in the event of power failure. The following CO line and extension cards can be used for Power Failure Connections: • Analog CO line card: ELCOT16 (4 PFT ports) • Extension card: EMSLC16 (4 PFT ports), ESLC16 (4 PFT ports), DHLC8 (2 PFT port) and SLC8 (2 PFT port) To 1 analog CO line card, connect only 1 extension card. Notes • • Power Failure Connections must be made within the same shelf. By programming the Hybrid IP-PBX, a CO line conversation established during power failure can be maintained even when the power returns and the connection is switched back to the normal configuration from the Power Failure Connection. However, if no special programming is performed, the connection will be dropped when power returns. RJ11 R2 T2 R1 T1 T1 R1 T2 R2 Co Line Card (e.g., ELCOT16) Extension Card (e.g., SLC8) To CO line To SLT Accessories and User-supplied Items Accessories (included): none User-supplied (not included): RJ11 connectors Installation Manual 203