4.1 Troubleshooting (Continued from the previous page.) Can you dial No out on a CO line? Connection between the central office and the Hybrid IP-PBX: CAUSE CO line is connected to the T2/T1. CO line T2 R1 T1 R2 Hybrid IP-PBX SOLUTION Reconnect the CO line to the T1/R1 or T2/R2 of the telephone jack using 2-conductor wiring. CO line is connected to the T2/R1. CO line T2 R1 T1 R2 Hybrid IP-PBX Installation Manual 221
4.1 Troubleshooting
Installation Manual
221
Connection between the central office and the Hybrid IP-PBX:
CAUSE
CO line is connected to the T2/T1.
CO line is connected to the T2/R1.
SOLUTION
Reconnect the CO line to
the T1/R1 or T2/R2 of the
telephone jack using
2-conductor wiring.
T2
R1
T1
R2
CO line
Hybrid IP-PBX
Hybrid IP-PBX
CO line
T2
R1
T1
R2
(Continued from the
previous page.)
Can you dial
out on a
CO line?
No