Sony MZ-NF610 Operating Instructions - Page 79
Insert an MD., Error message, Meaning/Remedy
View all Sony MZ-NF610 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 79 highlights
Error message LoBATT MEMORY NO CHG NoCOPY NoDISC NoEDIT NoMARK NO OPR No SIG PbONLY Rd ERR Meaning/Remedy • Battery is weak. , Replace the dry battery (page 18). • You tried to record with the recorder placed where it receives continuous vibration. , Put the recorder on a stable place, and start recording again. • You tried to charge at a place where the temperature is too high. , Charge the battery at a temperature of +5°C (+41°F) to +40°C (+104°F). • You tried to make a copy from a disc that is protected by the Serial Copy Management System. You cannot make copies from a digitally connected source which was itself recorded using digital connection. , Use analog connection instead (page 32). • You tried to play or record with no disc in the recorder. , Insert an MD. • You selected "G : Ers" with a disc without group setting. , You cannot erase groups with a disc with no groups. • You selected, "G : Set", "G : Rls", "Move", or "Erase" while recording. • You tried to erase the track mark at the beginning of the first track or group. • You tried to erase a track mark to combine tracks the recorder cannot combine (a track recorded in stereo and in mono, for example). • You tried to overwrite a track marks. • You selected bookmark play without setting bookmarks. , Set bookmarks (page 57). • You tried to set Auto Time Mark while recording through digital connection. • You tried to press X or T MARK during synchro-recording. • The recorder could not detect digital input signals. , Make sure that the source is connected firmly (page 23). • You tried to record or edit on a pre mastered MD (Pb stands for "playback"). , Insert a recordable MD. • The recorder cannot read the disc information correctly. , Reinsert the disc. 79