Sony STR DA5500ES Operating Instructions - Page 55
To save measurement results, that caused an error without, taking a remedy - problems
UPC - 027242754324
View all Sony STR DA5500ES manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
Getting Started Checking the auto calibration results If a warning message or error code appears in step 7 of "Performing auto calibration" (page 51), check the problem of the error and perform auto calibration again. 1 Press B/b to select "Yes," then press when "Error occurred during calibration, press to investigate." appears on the screen. Confirm the details of the measurement results, then proceed with the appropriate remedy. 2 Press B/b to select "Retry," then press . 3 Repeat steps 5 to 7 in "Performing auto calibration" (page 51). To save measurement results that caused an error without taking a remedy 1 Press B/b to select "No", then press when "Error occurred during calibration, press to investigate." appears on the screen. 2 Follow the steps in "Saving the measurement results" (page 54) to save the measurement results. Message list after auto calibration measurement Display Code 30 Code 31 Code 32 Code 33 Code 34 Warning 40 Warning 41 Warning 42 Warning 43 Explanation Headphones are connected. Remove the headphones and perform the auto calibration again. SPEAKERS (OFF/A/B/A+B) is set to OFF. Set it to others and re-perform the measurement. None of the speakers were detected. Make sure that the optimizer microphone is connected properly and reperform the measurement. If the optimizer microphone is connected properly but the error code appears, the optimizer microphone cable may be damaged or improperly connected. • None of the front speakers are connected or only one front speaker is connected. • The optimizer microphone is not connected. • Either the left or right surround speaker is not connected. • Surround back speakers are connected even though surround speakers are not connected. Connect the surround speaker(s) to the SURROUND terminals. • The surround back speaker is connected only to the SURROUND BACK SPEAKERS R terminals. When you connect only one surround back speaker, connect it to the SURROUND BACK SPEAKERS L terminals. Speakers are not placed in the proper position. Speakers or an optimizer microphone on the right or left may be placed wrongly. See "1: Installing speakers" (page 21) and check the speaker position. The measurement has completed. However, the noise level is high. You may be able to perform the measurement properly if you try it again, even though the measurement cannot be performed in all environments. Try to perform the measurement in a quiet environment. The input from the microphone is too big. • It may be too close the distance between the speaker and the microphone. Retry the measurement after setting apart from each other. • It may be that the volume is too big when you use the receiver as a preamp. The distance and position of a subwoofer cannot be detected. Or the angle of the speaker position cannot be detected. This may be caused by noise. Try to perform the measurement in a quiet environment. continued 55GB