4.27 Fluorescent Lamp 4 Replacement Procedure 6. Install the lamp cover (F) and secure it with the two screws (E). NOTE: Be careful not to make the lamp cover over the fitting pin. Around the pulling-out part of the lead wire, attach so that the P chassis is outside. (E) Screw tightening torque: 0.1176N•m (1.2kgf•cm) (F) Lamp cover (E) Figure 4-76 Replacing Sharp fluorescent lamp (SXGA+) (6) TECRA M2 Maintenance Manual (960-468) 4-103
4.27
Fluorescent Lamp
4
Replacement Procedure
6.
Install the lamp cover (F) and secure it with the two screws (E).
NOTE:
Be careful not to make the lamp cover over the fitting pin. Around the pulling-out
part of the lead wire, attach so that the P chassis is outside.
(E)
Screw tightening torque:
0.1176N
•
m (1.2kgf
•
cm)
(F) Lamp cover
(E)
Figure 4-76
Replacing Sharp fluorescent lamp (SXGA+) (6)
TECRA M2 Maintenance Manual (960-468)