Toshiba Tecra M2-S519 Maintenance Manual - Page 320
Replacement Procedure, Fluorescent Lamp, Replacing Sharp fluorescent lamp SXGA+ 9
View all Toshiba Tecra M2-S519 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 320 highlights
4 Replacement Procedure 4.27 Fluorescent Lamp 9. Install the protection cover S (A), protection cover G (B), aluminum tape (C) and fixing tape for lead wire (D). Use new parts. • Stick the protection covers in the order of (B), (A) to the standard line for fitting pin. • Stick the aluminum tape (C) following the sticking standards. Long sides: Stick to the mark-off line of the lamp cover on the back of bezel. Short sides: Stick to the edge of lamp cover. • Stick the fixing tape for lead wire (D) following the sticking standards. Long sides: Stick to the outline of the LCD module. Short sides: Stick so that the wire covers the screws. (B) Protection cover G (C) Aluminum tape Latch (A) Protection cover S (D) Fixing tape for lead wire Figure 4-79 Replacing Sharp fluorescent lamp (SXGA+) (9) 4-106 TECRA M2 Maintenance Manual (960-468)