ViewSonic CDE3201LED CDE3201LED User Guide (English) - Page 39

Send: Command Type= s

Page 39 highlights

Other Information 3. Protocol 3.1 Set-Function Listing The PC can control the LCD display for specific actions. The Set-Function command allows you to control the LCD display behavior in a remote sit through the RS232 port. The Set-Function packet format consists of 9 bytes. Set-Function description: Length: ID: Command Type: Command: Value[1~3]: CR: Total Byte of Message excluding "CR" Identification for each of LCD display If we want to set all settings, ID can use "99" to achieve, and it will not have Reply command on this function. The ID can be set via the OSD menu for each set. Identify command type, "s" (0x73h) : Set Command "+" (0x2Bh) : Valid command Reply "-" (0x2Dh) : Invalid command Reply Function command code: One byte ASCII code Three bytes ASCII that defines the value 0x0D Set-Function format: Send: (Command Type= "s") Name Length ID Byte Count 1 Byte 2 Byte Bytes order 1 2~3 Command Type 1 Byte 4 Command Value1 Value2 Value3 CR 1 Byte 5 1 Byte 1 Byte 1 Byte 1 Byte 6 7 8 9 Reply: (Command Type= "+" or "-") Name Length ID Command Type CR Byte Count 1 Byte 2 Byte 1 Byte 1 Byte Bytes order 1 2~3 4 5 [NOTE] The reply for "Power on" command is the exception. It's 0x322B0D ( 2+). Example1: Set Brightness as 76 for TV-02 and this command is valid Send (Hex Format) Name Hex Length 0x38 ID 0x30 0x32 Command Type Command Value1 Value2 0x73 0x24 0x30 0x37 Value3 0x36 CR 0x0D Reply (Hex Format) Name Hex Length 0x34 ID 0x30 0x32 Command Type 0x2B CR 0x0D 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

Other Information
30
3. Protocol
3.1 Set-Function Listing
The PC can control the LCD display for specific actions. The Set-Function command allows you to
control the LCD display behavior in a remote sit through the RS232 port. The Set-Function packet format
consists of 9 bytes.
Set-Function description:
Length:
Total Byte of Message excluding “CR”
ID:
Identification for each of LCD display
If we want to set all settings, ID can use “99” to achieve, and
it will not have Reply command on this function.
The ID can be set via the OSD menu for each set.
Command Type:
Identify command type,
“s” (0x73h) : Set Command
“+” (0x2Bh) : Valid command Reply
“-” (0x2Dh) : Invalid command Reply
Command:
Function command code: One byte ASCII code
Value[1~3]:
Three bytes ASCII that defines the value
CR:
0x0D
Set-Function format:
Send: (Command Type= “s”)
Name
Length
ID
Command
Type
Command
Value1
Value2
Value3
CR
Byte Count
1 Byte
2 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
Bytes order
1
2~3
4
5
6
7
8
9
Reply: (Command Type= “+” or “-”)
Name
Length
ID
Command Type
CR
Byte Count
1 Byte
2 Byte
1 Byte
1 Byte
Bytes order
1
2~3
4
5
[NOTE] The reply for “Power on” command is the exception. It’s 0x322B0D ( 2+<CR>).
Example1: Set Brightness as 76 for TV-02 and this command is valid
Send (Hex Format)
Name
Length
ID
Command Type
Command
Value1
Value2
Value3
CR
Hex
0x38
0x30
0x32
0x73
0x24
0x30
0x37
0x36
0x0D
Reply (Hex Format)
Name
Length
ID
Command Type
CR
Hex
0x34
0x30
0x32
0x2B
0x0D