Xerox 750DX 5750 Error Codes List - Page 15

Document Set Sensor.

Page 15 highlights

Status Code ADF "Other" Faults Description/Direction Use this RAP to troubleshoot ADF problems not covered by other RAPs. Initial action: Inspect the Document Set Sensor for contamination, foreign material or damage. Make sure the Document Set Sensor is installed correctly and that the actuator can move freely. Inspect the document tray for contamination or damage that would prevent the document from actuating the Document Set Sensor. If the problem still exists: Place a service call. 06-310, 311 The control logic sensed a communications failure between the IISS PWB and the IPS PWB (06-310), or the ADF PWB (06-311). Initial action: Switch off the machine power. If there is other equipment close by that may be generating electrical noise or radio frequency interference, power it off also. Contact Building Maintenance and have them verify the proper voltage at the machine plug. Clean and inspect all corotrons for defects and ensure they are properly installed Section 5-Repairs. Power the machine on. If the problem still exists: Place a service call. 5750 DocuCare Service Manual 5/98 2-15 Fault Code Procedures

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

5/98
5750 DocuCare Service Manual
2-15
Fault Code Procedures
ADF
“Other”
Faults
Use this RAP to troubleshoot ADF problems not covered by other RAPs.
Initial action:
Inspect the Document Set Sensor for contamination, foreign material or damage.
Make sure the Document Set Sensor is installed correctly and that the actuator can move freely.
Inspect the document tray for contamination or damage that would prevent the document from actuating the
Document Set Sensor.
If the problem still exists:
Place a service call.
06-310, 311
The control logic sensed a communications failure between the IISS PWB and the IPS PWB (06-310), or the ADF
PWB (06-311).
Initial action:
Switch off the machine power.
If there is other equipment close by that may be generating electrical noise or radio frequency interference,
power it off also.
Contact Building Maintenance and have them verify the proper voltage at the machine plug.
Clean and inspect all corotrons for defects and ensure they are properly installed Section 5-Repairs.
Power the machine on.
If the problem still exists:
Place a service call.
Status
Code
Description/Direction