Status Code 10-105, 106 Description/Direction The control logic sensed a timing error from the Fuser Exit Sensor. Initial action: Check for deformation of the Exit Chute (Lower/Upper). Check for paper path obstructions. Check for contamination, damage or wear on the Heat Roll (REP 5.31) and Pressure Roll (REP 5.35) surface. Check the Stripper Finger for defects and obvious damage (REP 5.38). If the problem still exists: Place a service call. 10-358 The control logic sensed an error from the Thermistor failure detection circuit. Initial action: Check the Heat Roll Control and Overheat Thermistors for cleanliness, damage and excessive wear at the point where the Thermistor contacts the Heat Roll (REP 5.37). Check the Pressure Roll Control and Overheat Thermistors for cleanliness, damage and excessive wear at the point where the Thermistor contacts the Pressure Roll (REP 5.37). If the problem still exists: Place a service call. 10-359 The control logic sensed an open circuit from the Heat Roll Control Thermistor. Initial action: Check the Heat Roll Control Thermistor for cleanliness, damage and excessive wear at the point where the Thermistor contacts the Heat Roll (REP 5.37). If the problem still exists: Place a service call. 5750 DocuCare Service Manual 5/98 2-29 Fault Code Procedures

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

5/98
5750 DocuCare Service Manual
2-29
Fault Code Procedures
10-105, 106
The control logic sensed a timing error from the Fuser Exit Sensor.
Initial action:
Check for deformation of the Exit Chute (Lower/Upper).
Check for paper path obstructions.
Check for contamination, damage or wear on the Heat Roll (REP 5.31) and Pressure Roll (REP 5.35) sur-
face.
Check the Stripper Finger for defects and obvious damage (REP 5.38).
If the problem still exists:
Place a service call.
10-358
The control logic sensed an error from the Thermistor failure detection circuit.
Initial action:
Check the Heat Roll Control and Overheat Thermistors for cleanliness, damage and excessive wear at the
point where the Thermistor contacts the Heat Roll (REP 5.37).
Check the Pressure Roll Control and Overheat Thermistors for cleanliness, damage and excessive wear at
the point where the Thermistor contacts the Pressure Roll (REP 5.37).
If the problem still exists:
Place a service call.
10-359
The control logic sensed an open circuit from the Heat Roll Control Thermistor.
Initial action:
Check the Heat Roll Control Thermistor for cleanliness, damage and excessive wear at the point where the
Thermistor contacts the Heat Roll (REP 5.37).
If the problem still exists:
Place a service call.
Status
Code
Description/Direction