Xerox 750DX 5750 Error Codes List - Page 27

Verify Heavy Weight Paper and Transparencies Control Panel settings are correct, if applicable.

Page 27 highlights

Status Code 08-385 Description/Direction The control logic sensed a timing error between the TR0 (Transfer Roll Zero) sensor and the IOT PWB. Initial action: Check the TR0 (Transfer Roll Zero) Sensor Actuator for damage (located inside and at the front of the CTR (Charged Transfer Roll) Assembly). If the problem still exists: Place a service call. 08-900 The control logic sensed a paper static jam. Initial action: Contact Building Maintenance and have them verify the proper voltage at the machine plug. Check Tray 1, 2, 3 or 4 for a cracked or broken tray stop. Clean the CTR (Charged Transfer Roll) Film with a dry cloth (REP 5.10). Verify Heavy Weight Paper and Transparencies Control Panel settings are correct, if applicable. If the problem still exists: Place a service call. 09-363 The control logic sensed a failure of the Developer Rotary Home Sensor to detect the position of the Developer Rotary. Initial action: Verify that the Drum unit is firmly seated and secured (REP 5.4). Inspect the installation of the Developer Units (REP 5.7). Make sure all screws are secure and that the clamps are in place If the problem still exists: Place a service call. 5750 DocuCare Service Manual 5/98 2-27 Fault Code Procedures

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

5/98
5750 DocuCare Service Manual
2-27
Fault Code Procedures
08-385
The control logic sensed a timing error between the TR0 (Transfer Roll Zero) sensor and the IOT PWB.
Initial action:
Check the TR0 (Transfer Roll Zero) Sensor Actuator for damage (located inside and at the front of the CTR
(Charged Transfer Roll) Assembly).
If the problem still exists:
Place a service call.
08-900
The control logic sensed a paper static jam.
Initial action:
Contact Building Maintenance and have them verify the proper voltage at the machine plug.
Check Tray 1, 2, 3 or 4 for a cracked or broken tray stop.
Clean the CTR
(Charged Transfer Roll) Film with a dry cloth (REP 5.10).
Verify Heavy Weight Paper and Transparencies Control Panel settings are correct, if applicable.
If the problem still exists:
Place a service call.
09-363
The control logic sensed a failure of the Developer Rotary Home Sensor to detect the position of the Developer
Rotary.
Initial action:
Verify that the Drum unit is firmly seated and secured (REP 5.4).
Inspect the installation of the Developer Units (REP 5.7). Make sure all screws are secure and that the
clamps are in place
If the problem still exists:
Place a service call.
Status
Code
Description/Direction