Xerox 750DX 5750 Error Codes List - Page 9

Clean and inspect all corotrons for defects and ensure they are properly installed Repairs

Page 9 highlights

Status Code 04-200 Description/Direction The control logic sensed that the IOT PWB detected a Machine Clock Failure. Initial action: Switch off the machine power. If there is other equipment close by that may be generating electrical noise or radio frequency interference, power it off also. Contact Building Maintenance and have them verify the proper voltage at the machine plug. Clean and inspect all corotrons for defects and ensure they are properly installed Section 5-Repairs. Power the machine on. If the problem still exists: Place a service call. 5/98 5750 DocuCare Service Manual 2-9 Fault Code Procedures

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

5/98
5750 DocuCare Service Manual
2-9
Fault Code Procedures
04-200
The control logic sensed that the IOT PWB detected a Machine Clock Failure.
Initial action:
Switch off the machine power.
If there is other equipment close by that may be generating electrical noise or radio frequency interference,
power it off also.
Contact Building Maintenance and have them verify the proper voltage at the machine plug.
Clean and inspect all corotrons for defects and ensure they are properly installed Section 5-Repairs.
Power the machine on.
If the problem still exists:
Place a service call.
Status
Code