Xerox 750DX 5750 Error Codes List - Page 32
the Thermistor contacts the Pressure Roll REP 5.37.
UPC - 042215455060
View all Xerox 750DX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
Status Code 10-366, 367 Description/Direction The control logic sensed that the Heat Roll temperature exceeded 180˚. Initial action: Check the Heat Roll Control Thermistor for cleanliness, damage and excessive wear at the point where the Thermistor contacts the Heat Roll (REP 5.37). If the problem still exists: Place a service call. 10-368 The control logic sensed an open circuit from the Pressure Roll control thermistor. Initial action: Check the Pressure Roll Control Thermistor for cleanliness, damage and excessive wear at the point where the Thermistor contacts the Pressure Roll (REP 5.37). If the problem still exists: Place a service call. 10-369 The control logic sensed an open circuit from the Pressure Roll overheat thermistor. Initial action: Check the Pressure Roll Control Thermistor for cleanliness, damage and excessive wear at the point where the Thermistor contacts the Pressure Roll (REP 5.37). If the problem still exists: Place a service call. Fault Code Procedures 5/98 2-32 5750 DocuCare Service Manual