Yamaha CVP-206 Owner's Manual - Page 141

Transmitting MIDI Data — Transmit, Clock, Transmit Clock, Receive Transpose, Start/Stop

Page 141 highlights

Making Global and Other Important Settings - Function Clock, Transmit Clock, Receive Transpose, Start/Stop ■ Clock Determines whether the CVP-206/204 is controlled by its own internal clock or a MIDI clock signal received from an external device. "INTERNAL" is the normal Clock setting when the CVP-206/204 is being used alone. If you are using the CVP-206/204 with an external sequencer, MIDI computer, or other MIDI device, and you want the CVP206/204 to be synchronized to the external device, set this function to "EXTERNAL." In the latter case, the external device must be connected to the CVP-206/204 MIDI IN terminal, and must be transmitting an appropriate MIDI clock signal. ■ Transmit Clock Turns MIDI clock transmission on or off. When this is set to "OFF," no MIDI clock or START/STOP data is transmitted. ■ Receive Transpose When this parameter is set to "OFF," note data received by the CVP-206/204 is not transposed, and when it is set to "ON," the received note data is transposed according to the current CVP-206/204 keyboard transpose (page 136) setting. ■ Start/Stop Determines whether incoming FA (start) and FC (stop) messages affect song or style playback. Message Switch FA, FC MIDI messages for starting/stopping the song or style. The "FA" message corresponds to start, and "FC" corresponds to stop. SYS/EX. Tx (TRANSMIT Turns MIDI transmission of MIDI system exclusive message data ON or OFF. SYS/EX. Rx (RECEIVE Turns MIDI reception of MIDI exclusive data generated by external equipment ON or OFF. CHORD SYS/EX. Tx (TRANSMIT) ...... Turns MIDI transmission of MIDI chord exclusive data (chord detect - root and type) ON or OFF. CHORD SYS/EX. Rx (RECEIVE).......... Turns MIDI reception of MIDI chord exclusive data generated by external equipment ON or OFF. Transmitting MIDI Data - Transmit This determines which parts will send MIDI data and over which MIDI channel the data will be sent. Determines the channel for changing transmit settings. Determines the Part for the selected channel. The dots corresponding to each channel (1-16) flash briefly whenever any data is transmitted on the channel(s). Turns transmission of the specified data type on or off. See below for details on the data types. Data Types in the MIDI TRANSMIT/RECEIVE Display Note Messages which are generated when the keyboard is played. Each message includes a specific note number which corresponds to the key which is pressed, plus a velocity value based on how hard the key is played. Control Change (CC) Control change data includes pedal and any other controller data. Program Change (PC) Program change data corresponds to voice or "patch" numbers. Pitch Bend (PB) See page 135. After Touch (AT)* With this function, the Clavinova senses how much pressure you apply to the keys while playing, and uses that pressure to affect the sound in various ways, depending on the selected voice. This allows you to play with greater expressiveness and add effects with your playing technique. * Available in RECEIVE display only (page 142). CVP-206/204 141

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172

Making Global and Other Important Settings — Function
141
CVP-206/204
Clock, Transmit Clock, Receive Transpose, Start/Stop
Clock
Determines whether the CVP-206/204 is controlled by its own internal clock or a MIDI clock signal received from
an external device. “INTERNAL” is the normal Clock setting when the CVP-206/204 is being used alone. If you are
using the CVP-206/204 with an external sequencer, MIDI computer, or other MIDI device, and you want the CVP-
206/204 to be synchronized to the external device, set this function to “EXTERNAL.” In the latter case, the external
device must be connected to the CVP-206/204 MIDI IN terminal, and must be transmitting an appropriate MIDI
clock signal.
Transmit Clock
Turns MIDI clock transmission on or off. When this is set to “OFF,” no MIDI clock or START/STOP data is
transmitted.
Receive Transpose
When this parameter is set to “OFF,” note data received by the CVP-206/204 is not transposed, and when it is set to
“ON,” the received note data is transposed according to the current CVP-206/204 keyboard transpose (page 136) setting.
Start/Stop
Determines whether incoming FA (start) and FC (stop) messages affect song or
style playback.
Message Switch
SYS/EX. Tx (TRANSMIT)
.....................
Turns MIDI transmission of MIDI system exclusive message data ON or OFF.
SYS/EX. Rx (RECEIVE)
........................
Turns MIDI reception of MIDI exclusive data generated by external equipment
ON or OFF.
CHORD SYS/EX. Tx (TRANSMIT)
......
Turns MIDI transmission of MIDI chord exclusive data (chord detect — root and
type) ON or OFF.
CHORD SYS/EX. Rx (RECEIVE)
..........
Turns MIDI reception of MIDI chord exclusive data generated by external
equipment ON or OFF.
Transmitting MIDI Data — Transmit
Data Types in the MIDI TRANSMIT/RECEIVE Display
* Available in RECEIVE display only (page 142).
Note
Messages which are generated when the keyboard is played. Each message includes a specific note number
which corresponds to the key which is pressed, plus a velocity value based on how hard the key is played.
Control Change (CC)
Control change data includes pedal and any other controller data.
Program Change (PC)
Program change data corresponds to voice or “patch” numbers.
Pitch Bend (PB)
See page 135.
After Touch (AT)*
With this function, the Clavinova senses how much pressure you apply to the keys while playing, and uses that
pressure to affect the sound in various ways, depending on the selected voice. This allows you to play with greater
expressiveness and add effects with your playing technique.
FA, FC
MIDI messages for starting/stop-
ping the song or style. The “FA”
message corresponds to start,
and “FC” corresponds to stop.
Determines the
channel for changing
transmit settings.
Determines the Part for the
selected channel.
Turns transmission of the
specified data type on or
off. See below for details
on the data types.
The dots corresponding
to each channel (1-16)
flash briefly whenever
any data is transmitted
on the channel(s).
This determines which parts will
send MIDI data and over which
MIDI channel the data will be sent.