Yamaha CVP-701 CVP-701 Reference Manual - Page 96

Local Control, Clock setting, etc., CLOCK, TRANSMIT CLOCK, RECEIVE TRANSPOSE, START/STOP

Page 96 highlights

MIDI Settings The explanations here apply to the SYSTEM Page in step 4 on page 94. Use the [A]/[B] buttons to select the parameters (below), then set the ON/OFF status by using the [1] - [8] buttons. Connections - Using Your Instrument with Other Devices - 11 1 Local Control Turns the Local Control for each part on or off. When Local Control is set to "ON," the keyboard of the instrument controls its own (local) internal tone generator, allowing the internal Voices to be played directly from the keyboard. If you set Local to "OFF," the keyboard and controllers are internally disconnected from the instrument's tone generator section so that no sound is output when you play the keyboard or use the controllers. For example, this allows you to use an external MIDI sequencer to play the instrument's internal Voices, and use the instrument keyboard to record notes to the external sequencer and/or play an external tone generator. 2 Clock setting, etc.  CLOCK Determines whether the instrument is controlled by its own internal clock or a MIDI clock signal received from an external device. INTERNAL is the normal Clock setting when the instrument is being used alone or as a master keyboard to control external devices. If you are using the instrument with an external sequencer, MIDI computer, or other MIDI device, and you want to synchronize it to that device, set this parameter to the appropriate setting: MIDI, USB 1, or USB 2. In this case, make sure that the external device is connected properly (e.g., to the instrument's MIDI IN terminal), and that it is properly transmitting a MIDI clock signal. When this is set for control by an external device (MIDI, USB 1 or USB 2), the Tempo is indicated as "Ext." in the Main display. NOTE If the Clock is set to something other than INTERNAL, the Style or Song cannot be played from the panel buttons. NOTE When a USB wireless LAN adaptor is connected to the [USB TO DEVICE] terminal, the "WIRELESS LAN" parameter can also be selected.  TRANSMIT CLOCK Turns MIDI clock (F8) transmission on or off. When set to OFF, no MIDI clock or Start/Stop data is transmitted even if a Song or Style is played back.  RECEIVE TRANSPOSE Determines whether or not the instrument's transpose setting is applied to the note events received by the instrument via MIDI.  START/STOP Determines whether incoming FA (start) and FC (stop) messages affect Song or Style playback. 3 MESSAGE SW (Message Switch)  SYS/EX. The "Tx" setting turns MIDI transmission of MIDI System Exclusive messages on or off. The "Rx" setting turns MIDI reception and recognition of MIDI System Exclusive messages generated by external equipment on or off. 96 CVP-701 Reference Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

96
CVP-701 Reference Manual
Connections – Using Your Instrument with Other Devices –
11
MIDI Settings
The explanations here apply to the SYSTEM Page in step 4 on
page 94
.
Use the [A]/[B] buttons to select the parameters (below), then set the ON/OFF status by using the [1

] –
[8

] buttons.
1 Local Control
Turns the Local Control for each part on or off. When Local Control is set to “ON,” the keyboard of the
instrument controls its own (local) internal tone generator, allowing the internal Voices to be played
directly from the keyboard. If you set Local to “OFF,” the keyboard and controllers are internally
disconnected from the instrument’s tone generator section so that no sound is output when you play the
keyboard or use the controllers. For example, this allows you to use an external MIDI sequencer to play
the instrument’s internal Voices, and use the instrument keyboard to record notes to the external sequencer
and/or play an external tone generator.
2 Clock setting, etc.
CLOCK
Determines whether the instrument is controlled by its own internal clock or a MIDI clock signal received
from an external device. INTERNAL is the normal Clock setting when the instrument is being used alone
or as a master keyboard to control external devices. If you are using the instrument with an external
sequencer, MIDI computer, or other MIDI device, and you want to synchronize it to that device, set this
parameter to the appropriate setting: MIDI, USB 1, or USB 2. In this case, make sure that the external
device is connected properly (e.g., to the instrument’s MIDI IN terminal), and that it is properly
transmitting a MIDI clock signal. When this is set for control by an external device (MIDI, USB 1 or USB
2), the Tempo is indicated as “Ext.” in the Main display.
NOTE
If the Clock is set to something other than INTERNAL, the Style or Song cannot be played from the panel buttons.
NOTE
When a USB wireless LAN adaptor is connected to the [USB TO DEVICE] terminal, the “WIRELESS LAN” parameter can also be selected.
TRANSMIT CLOCK
Turns MIDI clock (F8) transmission on or off. When set to OFF, no MIDI clock or Start/Stop data is
transmitted even if a Song or Style is played back.
RECEIVE TRANSPOSE
Determines whether or not the instrument’s transpose setting is applied to the note events received by the
instrument via MIDI.
START/STOP
Determines whether incoming FA (start) and FC (stop) messages affect Song or Style playback.
3 MESSAGE SW (Message Switch)
SYS/EX.
The “Tx” setting turns MIDI transmission of MIDI System Exclusive messages on or off. The “Rx” setting
turns MIDI reception and recognition of MIDI System Exclusive messages generated by external
equipment on or off.