Not in Use, Enter, Rebuild, Degraded Disk Array Warning Message
UPC - 693494971613
View all 3Ware 9550SXU16MLB10 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 139 highlights
Rebuilding Units Figure 48. Degraded Disk Array Warning Message 2 Press a key to continue. 3 If your degraded unit has a drive indicated as Not in Use, the drive may still be usable. Try rebuilding with the Not in Use drive intact. Simply select the unit (highlight it and press Enter) and then select the Rebuild Unit button. 4 When the Rebuild confirmation screen appears, confirm that you selected the correct unit by selecting OK. 5 Press F8 to save your changes and exit 3BM. The unit will begin rebuilding after the operating system finishes loading. If the rebuild fails and you have no available drives, you must power down the system and replace the failed or Not In Use drive. Then power on the system and start 3BM. 1 At the main 3BM screen, highlight an available drive to replace the faulted drive and press Enter to select it (see Figure 49). An asterisk appears in the left most column to indicate the drive is selected. 2 Press Tab to select the degraded unit and press Enter to select it. www.3ware.com 133