3Ware 9550SXU16MLB10 User Guide - Page 178

Aen 032h Aen_spare_inadequate, Aen 036h Aen_verify_error, Aen 037h Aen_incompatible_sodimm

Page 178 highlights

Troubleshooting: Problems and Solutions AEN 032h AEN_SPARE_INADEQUATE This AEN is sent by the controller when it finds a valid hot spare but the capacity is not sufficient to use it for a drive replacement. AEN 036h AEN_VERIFY_ERROR This AEN is sent by the controller when a verify error is found (parity inconsistency for RAID5/50 or data mismatch for RAID1/10 configuration) and recovered. If the error is not recovered the AEN_VERIFY_FAILED is returned instead. AEN 037h AEN_INCOMPATIBLE_SODIMM This AEN will be sent if an incompatible SODIMM memory has been connected to the controller. In this case, the controller is inoperable. AEN 038h AEN_NO_SODIMM This AEN will be sent if there is no SODIMM memory connected to the controller. In this case, the controller is inoperable. AEN 039h AEN_COR_SBUF_ECC This AEN will be sent when the controller has detected and corrected a memory ECC error. AEN 03Ah AEN_DRIVE_POR_DETECTED If the controller detects that a drive has been power-cycled, it will send this AEN. The controller may degrade the unit (if possible). AEN 03Bh AEN_REBUILD_PAUSED This AEN will be sent when the rebuild operation is paused. AEN 03Ch AEN_INIT_PAUSED This AEN will be sent when the initialization is paused. AEN 03Dh AEN_VERIFY_PAUSED This AEN will be sent when the verify operation is paused. AEN 03Fh AEN_FLASH_FILE_CORRUPT The 3ware RAID controller stores some configuration parameters as files in its flash memory. This AEN will be sent when a corrupted flash file system is found on the controller during boot-up. A further attempt will be made to 172 3ware 9000 Series Serial ATA RAID Controller User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202

Troubleshooting: Problems and Solutions
172
3ware 9000 Series Serial ATA RAID Controller User Guide
AEN 032h AEN_SPARE_INADEQUATE
This AEN is sent by the controller when it finds a valid hot spare but the
capacity is not sufficient to use it for a drive replacement.
AEN 036h AEN_VERIFY_ERROR
This AEN is sent by the controller when a verify error is found (parity
inconsistency for RAID5/50 or data mismatch for RAID1/10 configuration)
and recovered. If the error is not recovered the AEN_VERIFY_FAILED is
returned instead.
AEN 037h
AEN_INCOMPATIBLE_SODIMM
This AEN will be sent if an incompatible SODIMM memory has been
connected to the controller. In this case, the controller is inoperable.
AEN 038h
AEN_NO_SODIMM
This AEN will be sent if there is no SODIMM memory connected to the
controller. In this case, the controller is inoperable.
AEN 039h
AEN_COR_SBUF_ECC
This AEN will be sent when the controller has detected and corrected a
memory ECC error.
AEN 03Ah
AEN_DRIVE_POR_DETECTED
If the controller detects that a drive has been power-cycled, it will send this
AEN. The controller may degrade the unit (if possible).
AEN 03Bh
AEN_REBUILD_PAUSED
This AEN will be sent when the rebuild operation is paused.
AEN 03Ch
AEN_INIT_PAUSED
This AEN will be sent when the initialization is paused.
AEN 03Dh
AEN_VERIFY_PAUSED
This AEN will be sent when the verify operation is paused.
AEN 03Fh AEN_FLASH_FILE_CORRUPT
The 3ware RAID controller stores some configuration parameters as files in
its flash memory. This AEN will be sent when a corrupted flash file system is
found on the controller during boot-up. A further attempt will be made to