Bosch VIPX1 Operation Manual - Page 125
iSCSI connections malfunctions, Alarm sources, Alarm connections, Malfunction, Possible causes - firmware
View all Bosch VIPX1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 125 highlights
VIP X1 | Installation and Operating Manual EN | 125 Malfunction Possible causes Solution The unit does not report an alarm. Alarm source is not selected. Select possible alarm sources on the Alarm sources configuration page. No alarm response specified. Specify the desired alarm response on the Alarm connections configuration page, change the IP address if necessary. Control of cameras or other units is not possible. The cable connection Check all cable connections and between the serial interface ensure all plugs are properly fitted. and the connected unit is not correct. The interface parameters do Make sure that the settings of all not match those of the other units involved are compatible. unit connected. The unit is not opera- Power failure during protional after a firm- gramming by firmware file. ware upload. Have the unit checked by Customer Service and replace if necessary. Incorrect firmware file. Enter the IP address of the unit followed by /main.htm in your Web browser and repeat the upload. iSCSI connections malfunctions Malfunction Possible causes Solution No LUNs are displayed after connection to the iSCSI server. Incorrect LUN mapping during iSCSI server configuration. Check the iSCSI server configuration and reconnect. „LUN FAIL" is displayed below a node after connection to the iSCSI server. The LUN map was not read- Check the iSCSI server configuraable as it was assigned to tion and reconnect. the wrong network interface. LUN mapping is not Some iSCSI systems don't Delete the initiator extension on the possible. support initiator extensions. iSCSI settings configuration page. Bosch Security Systems | 2006-12 | V2.5 Appendix