Specifications, Device, CE: IEC 60950; UL 1950; AS/NZS 3548
View all Bosch VIPX1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 135 highlights
VIP X1 | Installation and Operating Manual Specifications EN | 135 Device Operating voltage Power consumption LAN interface Data interfaces Alarm inputs Relay output Video input Audio input (Line In) Audio output (Line Out) Microphone input Speaker output Displays Operating conditions Regulatory approvals 12 ... 24 V DC, power supply unit with various primary adapters included PoE: IEEE 802.11af, class 2 Approx. 6 VA 1 × Ethernet 10/100 Base-T, automatic adjustment, half/full duplex, RJ45 1 × RS232/RS422/RS485, bidirectional, ST500 1 × USB 2.0 4 × push-in terminals (non-isolated closing contact), maximum trip resistance 10 Ohm 1 × push-in terminal, 30 Vp-p, 2 A 1 × BNC jacks 0.7 ... 1.2 Vp-p, 75 Ohm, PAL/NTSC 1 × 3.5 mm stereo jack socket, 5.5 Vp-p max., impedance 9 kOhm typ. 1 × 3.5 mm stereo jack socket, 3 Vp-p max., impedance 16 Ohm min. 1 × push-in terminal, 2.8 Vp-p max. at -20 dB, impedance 2 kOhm typ., supply 2.3 V typ. 1 × push-in terminal, 6 Vp-p max., 1 W rms, impedance 4 Ohm min. 3 × LED (operating voltage, network connection, data transfer) in rear panel Temperature: 0 ... +50°C (+32 ... +122°F) relative humidity: 20 ... 80%, non-precipitating CE: IEC 60950; UL 1950; AS/NZS 3548; EN 55103-1, -2; EN 55130-4; EN 55022; EN 55024; EN 61000-3-2; EN 61000-3-3; FCC 47 CFR Chapter 1 Part 15 Bosch Security Systems | 2006-12 | V2.5 Appendix